Removal and replacement procedures 28
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To remove the component:
1.
Back up all server data on the drive.
2.
Unlock and remove the tower bezel ("
" on page
3.
Determine the status of the drive from the Hot-plug drive LED definitions (on page
4.
Remove the drive.
To replace the component, reverse the removal procedure.
Non-hot-plug drive
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To remove the component:
1.
Back up all server data on the drive.
2.
Unlock and remove the tower bezel ("
" on page
3.
Power down the server (on page
4.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
5.
Place the server on its side.
6.
Remove the access panel (on page
7.
If installed, remove the PCI air baffle (on page
8.
Remove the system air baffle (on page
9.
Remove the fans (on page
10.
Disconnect the drive cables from the rear of the drives.
11.
Remove the non-hot-plug drive cage from the server: