Error messages 142
1720-S.M.A.R.T. Hard Drive Detects Imminent Failure
Audible Beeps
: None
Possible Cause
: A hard drive SMART predictive failure condition is detected. It may fail at some time in
the future.
Action
:
•
If configured as a non-RAID 0 array, replace the failing or failed drive. Refer to the server
documentation.
•
If configured as a RAID 0 array or non-RAID setup, back up the drive or drives, replace the drive,
and restore the system.
1721-Slot X Drive Array - Drive Parameter Tracking Predicts Imminent Failure...
...The following devices should be replaced when conditions permit. Do not replace drive unless all other drives in
the array are on-line! Back up data before replacing drive(s) if using RAID 0.
Audible Beeps
: None
Possible Cause
: Drive parameter tracking reports a predictive-failure condition on the indicated drive. It
may fail at some time in the future.
Action
:
•
If the drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive
and restore all data afterward.
•
If the drive is part of a fault-tolerant configuration, do not replace the drive unless all other drives in
the array are online.
1724-Slot X Drive Array - Physical Drive Position Change(s) Detected - ...
...Logical drive configuration has automatically been updated.
Audible Beeps
: None
Possible Cause
: The logical drive configuration has been updated automatically following physical drive
position changes.
Action
: No action is required.
1725-Slot X Drive Array-Optional SIMM Failure Detected
Audible Beeps
: None
Possible Cause
: SIMM has been automatically disabled due to memory errors or unsupported SIMM type
installed.
Action
: Replace the SIMM memory module on the indicated controller.
1726-Slot X Drive Array - Array Accelerator Memory Size Change Detected. - ...
...Array Accelerator configuration has automatically been updated.