Error messages 99
Identify Logical Drive Data did not Match with NVRAM
Description
: The identify unit data from the array controller does not match with the information stored in
NVRAM. This can occur if new, previously configured drives have been placed in a system that has also
been previously configured.
Action
: Run the server setup utility to configure the controller and NVRAM.
Insufficient adapter resources
Description
: The adapter does not have sufficient resources to perform posted-write operations to the array
accelerator board. Drive rebuild may be occurring.
Action
: Operate the system without the array accelerator board until the drive rebuild completes.
Inter-Controller Link Connection Could Not Be Established
Description
: Unable to communicate over the link connecting the redundant controllers.
Action
: Be sure both controllers are using the same hardware and firmware revisions. If one controller
failed, replace it.
Less Than 75% Batteries at Sufficient Voltage
Description
: The operation of the array accelerator board has been disabled due to less than 75% of the
battery packs being at the sufficient voltage level.
Action
: Replace the array accelerator board if the batteries do not recharge within 36 powered-on hours.
Less Than 75% of Batteries at Sufficient Voltage Battery Pack X Below Reference
Voltage
Description
: Battery pack on the array accelerator is below the required voltage levels.
Action
: Replace the array accelerator board if the batteries do not recharge within 36 powered-on hours.
Logical Drive X Failed Due to Cache Error
Description
: This logical drive failed due to a catastrophic cache error.
Action
: Replace the array accelerator board and reconfigure using ACU ("
Array Configuration Utility
" on
page
70
).
Logical Drive X Status = Failed
Description
: This status could be issued for several reasons:
•
Logical drive is configured for No Fault Tolerance, and one or more drives failed.
•
Mirroring is enabled, and any two mirrored drives failed.
•
Data Guarding is enabled, and two or more drives failed.
•
Another configured logical drive is in the WRONG DRIVE REPLACED or LOOSE CABLE DETECTED
state.