Industry Standard
Compliance
ACPI 2.0b Compliant
PCIe 2.0 Compliant
WOL Support
Microsoft® Logo certifications
PXE Support
USB 1.1 and 2.0 Compliant
SMBIOS 2.6.1
Server Power Cords
6' Highline (IEC-IEC) power cord ships standard
NOTE:
HP ProLiant SL servers are primarily connected to PDU's in data center racks so they ship standard
with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant SL server using a 110V
receptacle (NEMA-15), the NEMA power cord must be ordered separately.
NOTE:
If customers require a power cord, they can check the power cord matrix for the appropriate cord.
Please see the following power cord matrix:
http://www.hp.com/go/powercordmatrix
.
Power Specifications
To review typical system power ratings use the HP Power Advisor which is available via the online tool
located at URL:
www.hp.com/go/proliant-energy-efficient
or
www.hp.com/go/hppoweradvisor
.
NOTE:
Power Specification and Technical Content for supported power supplies can be found at:
http://h18000.www1.hp.com/products/quickspecs/14209_ca/14209_ca.html
Common Slot Power
Supply
HP's Common Slot (CS) power supplies allow for commonality of power supplies across a wide range of
ProLiant and Integrity servers, as well as HP Storage solutions, and are designed to provide the highest
power supply efficiency without degrading system performance. HP CS power supplies are tested by the
Electric Power Research Institute (EPRI) and certified through the ECOS 80 Plus power supply program. HP
CS power supply options provide efficiency ratings of up to 94% and are available in two power output
options - 750W, and 1200W - allowing the user to "right-size" a power supply for their specific server
configuration. All HP Common Slot power sources are UL, CE Mark Compliant, hot-plug and support
redundant configurations. It is highly recommended that you use the HP Power Advisor in defining the
"Right-Size" power supply for your needs. HP Power Advisor can be accessed at:
www.hp.com/go/hppoweradvisor
.
NOTE:
Mixing of power supplies in the same server is not supported. All power supplies must be of the
same output and efficiency rating. If non-matched power supplies are inserted you will get errors and
operation will fail.
NOTE:
The 80 PLUS program is a unique forum that unites electric utilities, the computer industry, and
consumers in an effort to bring energy efficient technology solutions to the marketplace. 80 Plus
independently tests power supply efficiency and publicly posts the results on
www.80Plus.org
.
NOTE:
Redundant Power: Optional redundant power supplies can be purchased through power supply
option kits (see Power Supplies for part numbers).
QuickSpecs
HP ProLiant SL4540 Generation 8 (Gen8) Server
Standard Features
DA - 14406 Canada — Version 19 — June 10, 2014
Page 9