37
Note:
In Adaptec Storage Manager, logical disks are labeled 1, 2,
and 3. In Disk Manager, logical disks are displayed as 0, 1, and 2.
The default configuration for the data volume can be modified using
the Disk Management utility. Refer to the administration guide for
additional information.
The BIOS supports the following default boot sequence:
1. USB CD-ROM
2. HDD 0, 1, 2
Note:
This is logical drive 1, 2, and 3 as presented by the SATA RAID
controller.
3. PXE
Table 7: RAID configuration by logical drives
Logical Drive 1
Partition C: 9GB Primary OS - RAID 1
Mirror spanning physical drives 0 and 1
Logical Drive 2
Partition D: 9GB Secondary OS - RAID 1
Mirror spanning physical drives 2 and 3
Logical Drive 3
Partition F: Data volume using remaining
disk space - RAID 5 volume spanning
physical drives 0, 1, 2, and 3