4.  Insert the screws supplied in the UPS kit through each 

rack-mounting rail and into the front of each rack. 

 

 

5.  Insert the screws into the back of each rail and through the cage 

nuts that were installed in step 3. 

 

 

6. Install the rear stabalization bracket. 

 

 

Installing the UPS in the Rack 

Before attempting to install the UPS, review and adhere to all 
warnings provided in the “Important Safety Information” section 
of this document. 
To install the UPS in the rack: 
1.  With one person on each side of the carton, remove the UPS 

chassis using the lift-out tray.  

2.  Gently lower the chassis to the floor in front of the rack. 
3.  Cut the band holding the chassis, freeing it from the  

lift-out tray. 

4.  With one person on each side, lift the chassis to rail level and 

slide it into place on the mounting rail. 

5.  Attach the chassis to the rack using the screws and the cage 

nuts supplied with the rack. 

 

NOTE:

  After installing the UPS chassis, insert additional screws for support 

if any screw holes are unoccupied. 

 

Completing the UPS Assembly 

Connecting the Communications Port 

The UPS includes a communications port that allows the unit to 
exchange data with the host computer. 

 

IMPORTANT:

  Power management software requires the communications 

port to be appropriately cabled to the host computer. 

 

Connect the UPS/computer interface cable (supplied) from the 
communications port on the UPS to the appropriate 
communications port on the host computer. 

 

CAUTION:

  Use only the specific cable supplied with the UPS to 

connect the communications port to the host computer. 

 

 

Summary of Contents for R1500 XR SERIES

Page 1: ...onductor leakage current Do not operate a UPS that is disconnected from the utility power source Disconnect protected devices from the UPS before disconnecting the UPS from utility power Use the Test Alarm Reset button to test the batteries rather than unplugging the UPS Refer to the UPS user guide for more information on the operation of the UPS Regulatory Compliance Identification Numbers For re...

Page 2: ...te tool 2U 295523 023 UPS UPS chassis Front bezel Rear stabilization brackets 2 Remote Emergency Power Off REPO port and connector block Battery pack 1 Additional Hardware The following items are supplied for shipping a rack with a UPS installed M6 nuts 4 M6 flat washers 4 M6 split washers 4 Cables The R1500 XR NA model ships with a non detachable input power cord with a NEMA 5 15 plug and a 3 66 ...

Page 3: ...near the rack where it will be assembled Follow the unpacking instructions on the carton Mounting the Rails The UPS must be mounted on the fixed rails supplied with the UPS Before beginning this installation process review and adhere to the following precautions WARNING To prevent personal injury verify that the rack containing the UPS is stable The following conditions must be met The leveling fe...

Page 4: ...lift out tray 4 With one person on each side lift the chassis to rail level and slide it into place on the mounting rail 5 Attach the chassis to the rack using the screws and the cage nuts supplied with the rack NOTE After installing the UPS chassis insert additional screws for support if any screw holes are unoccupied Completing the UPS Assembly Connecting the Communications Port The UPS includes...

Page 5: ...m a remote location To activate the REPO port 1 Install a suitable switch at the required remote location 2 Remove the connector block from the REPO port 3 Wire the connector block using stranded non shielded wire AWG 22 18 or equivalent 4 Replace the connector block in the REPO port IMPORTANT The REPO port must meet the requirements of the NFPA Articles 645 10 and 645 11 for a disconnecting means...

Page 6: ... NOTE The Configure Mode On LED the Configure button and the voltage configuration panel are accessible only when the front bezel is removed Utility LED 5 Flashing Red Utility input voltage is outside the 20 to 30 configured nominal range Green Utility voltage is present and output is on or utility voltage has returned to the voltage range that was configured UPS is supplying utility power and aud...

Page 7: ... Press the Standby button to take the UPS out of Operate mode Power to the load receptacles ceases 3 Disconnect the UPS from utility power 4 Wait at least 60 seconds while the UPS internal circuitry discharges For more information refer to the HP website at www hp com products ups ...

Reviews: