background image

8

Operation (Continued)

hole of 1/4 size. An optional exter-
nal bypass plug (Figure 5 & 7, Ref.
No. 14 included) should be inserted
in this hole and bottomed out. The
open 1/4 NPT port must now be
piped back to the tank or well
downstream of the pump suction.

10. For operation of the pump with

pressure relief valve in reverse rota-
tion, the motor may be reversed,
allowing for reverse rotation.
Standard models are equipped with
pressure relief valves and the pump
can be run in reverse, however, the
pressure relief valve will not func-
tion. For continuous reverse rota-
tion, the cover plate must be rotat-
ed 180˚. This is accomplished by
removing the six cover plate screws,
rotating the cover plate, and reat-
taching the screws. The relief valve
should now be on the opposite side.
This will allow operation of the
pump with a functioning pressure
relief valve in reverse rotation.

Maintenance

Make certain that the 

power source is discon-

nected before attempting to service or disas-
semble any components! If the power discon-
nect is out of sight, lock it in the open position
and tag to prevent application of power.

GENERAL

Check the pump for proper operation
daily, weekly, monthly, etc. If anything
has changed (pump noise, motor noise,
leaks, etc.) since the pump was new, the
pump should be removed, examined and
repaired if necessary. This is a difficult
motor/pump to repair, therefore, only
qualified electricians or service techni-
cians should attempt to repair this unit.
Improper repair and/or assembly can
cause problems with the electric motor
used with this unit. See General Safety
Information.

Retighten the ”V“ band clamp screw as
necessary. Use Loctite or similar thread
sealant if screw keeps coming loose.

Rotary gear pumps must be drained
completely if subject to freezing 
temperature and should not be 
operated until temperature permits.

To store the pump, place a small quantity
of light oil or some other storage preser-
vative compatible with your application
in the pump and rotate the shaft very
slowly to work the oil throughout the
gears and the body.

DISASSEMBLY AND ASSEMBLY

Refer to Figure 7 for parts identification
during disassembly and assembly.
[Assumes pump is separated from
motor and that Oldham coupling 
(Ref. No. 24) is removed.]

1. Remove screws (Ref. No. 3) and

cover (Ref. No. 2). Refer to 
INSPECTION procedures below.

2. Lift out idler shaft (Ref. No. 8).

3. Remove internal retaining ring (Ref.

No. 12) from drive end of the pump
body (Ref. No. 1) using TruArc-type
internal snap-ring pliers.

4. Carefully pry out ceramic seat (Ref.

No. 11) and then seal (parts of 
seal seat assembly using a suitable
hooked tool).

Bronze Models GCBN2V, GCBN3V, GCBN22V and GCBN33V

Cast Iron Models GCCV2V, GCCV3V, GCCV22V and GCCV33V

Shertech Operating Instructions, Performance, 
Specifications and Parts Manual

Form L-4083 (1/06)

Carbonator-Mount Rotary

Close-Coupled External Gear Pumps

Summary of Contents for Shertech GCBN22V

Page 1: ...or use with oil based fluids Not to be used with water based fluids Pumps include steel spur gears with steel shafts and cast iron shaft support standard pressure relief valves that can be ported internally or externally and a Viton mechanical carbon ceramic faced seal with temperature range of 32 to 280 F Wet end parts are constructed from cast iron steel stainless steel 302 303 and or 18 8 carbo...

Page 2: ...HP 3 1 2 HP V Pressure Relief Valve Standard 1st 2nd 3rd 4th 5th 6th Mounting Material Sealing Gear Size Ports AC Motor Options NOTE Not all order code combinations configurations are standard models available from the manufacturer Custom model configurations may require ordering standard components and or optional parts that will need to be assembled by the customer Manufacturer reserves the righ...

Page 3: ... by 10 Don t use water with Cast Iron Pump performance when pump is new As pump wears the performance will decrease NPT inlet and outlet in inches Suction lift requires wetted gears and primed seal chamber Motor not provided NOTES Pumps with motors are HP rated to handle up to 500 SSU at 100 PSI and specific gravity of 1 0 Max PSI 100 Max Viscosity 500 SSU Max RPM 1725 Max Specific Gravity 1 1 at ...

Page 4: ...5 3 8 CI CRS CRS CI CRS SS Viton Mech 22 3 Models without Motors GCBN2V 48Y 1725 1 4 BZ BZ 303 SS CG BR SS Buna Mech 4 3 GCBN3V 48Y 1725 3 8 BZ BZ 303 SS CG BR SS Buna Mech 4 8 GCCV2V 48Y 1725 1 4 CI CRS CRS CI CRS SS Viton Mech 4 0 GCCV3V 48Y 1725 3 8 CI CRS CRS CI CRS SS Viton Mech 4 3 BZ Bronze BR Brass CG Carbon Graphite CI Cast Iron CRS Cold Rolled Steel ODP Open Drip Proof Motor not provided...

Page 5: ...3 4 11 16 35 8 21 2 GCBN33V GCCV33V 3 8 21 4 27 16 3 7 89 16 23 4 55 8 41 4 53 4 11 16 35 8 21 2 Models without Motors GCBN2V GCCV2V 1 4 129 32 3 69 16 35 8 21 2 GCBN3V GCCV3V 3 8 21 4 3 7 35 8 21 2 NPT inlet and outlet in inches This dimension may vary due to motor manufacturer s specifications NOTE Dimensions have a tolerance of or 1 8 Manufacturer reserves the right to change dimensions without...

Page 6: ... Locate the pump as close to the liquid source as possible making the suction line as short and direct as possible Ambient temperature around motor should not exceed 104 F 40 C 2 Open drip proof motors are designed to be used in clean dry locations with access to an adequate supply of cooling air 3 For outdoor installations the motor must be protected by a cover that does not block air flow to and...

Page 7: ...s and this tolerance must not be altered The liquids must therefore be free of all abrasives Sand silt wettable powders etc must be avoided NOTE Cast iron pumps are for oil based fluids only 3 When pumping a more viscous beyond 500 SSU liquid a slower speed a larger pipe size pump and possibly a larger motor should be selected NOTE See performance chart for Max Torque 4 Recheck motor rotation Prop...

Page 8: ... is a difficult motor pump to repair therefore only qualified electricians or service techni cians should attempt to repair this unit Improper repair and or assembly can cause problems with the electric motor used with this unit See General Safety Information Retighten the V band clamp screw as necessary Use Loctite or similar thread sealant if screw keeps coming loose Rotary gear pumps must be dr...

Page 9: ...d Do not run pump dry as permanent damage to the pump gears seal and bearings will result Suction pressure should never be greater than the discharge pressure Mechanical Seal Replacement Refer to Figures 6 7 for parts identification 1 Remove pump from motor if not already done 2 Remove snap ring Ref No 12 Pry out seal seat Ref No 11 Pull mechanical seal Ref No 10 off shaft See Assembly 3 through 5...

Page 10: ...t the pump head be replaced Note that seals and o rings used in each material type are interchangeable The Viton components from the cast iron models can be used in the bronze and the Buna in the bronze models can be used in the cast iron models Figure 7 Repair Parts Illustration Please provide following information Model number Serial number if any Part description and number as shown in parts li...

Page 11: ...A NA NA NA NA NA 1 14 External Bypass Relief Plug NA NA NA NA NA NA NA NA 1 15 Relief Valve Cap NA NA NA NA NA NA NA NA 1 16 Washer NA NA NA NA NA NA NA NA 1 17 Hex Nut NA NA NA NA NA NA NA NA 1 18 Set Screw 18 8 SS NA NA NA NA NA NA NA NA 1 19 O ring NA NA NA NA NA NA NA NA 1 20 O ring Retainer NA NA NA NA NA NA NA NA 1 21 O ring NA NA NA NA NA NA NA NA 1 22 Spring 302 SS NA NA NA NA NA NA NA NA ...

Page 12: ...cals must be labeled before being shipped to Hypro for service or warranty consideration Hypro reserves the right to request a Material Safety Data sheet from the Purchaser for any pump or product Hypro deems necessary Hypro reserves the right to disposition as scrap pumps or products returned without authorization and or which contain unknown substances or to charge for any and all costs incurred...