Solution
Possible causes
Symptom
Refer to the Microsoft website at:
http://support.microsoft.com/
default.aspx?scid=
kb;en-us;842411
or complete the
following steps to disable RSM
polling:
1.
Install the 1.0.4.0 or later
driver.
2.
Disable device polling in the
system registry.
• Establish a CLI session.
• Log into the system as
Ad-
ministrator
.
• Run
RegEdit
and navigate
to the following registry:
HKEY_LOCAL_MACHINE\
SYSTEM\CurrentCon-
trolSet\Services\
hplto.
• To disable RSM polling,
edit the
AutoRun
value
found in this key. A value
of
0
(zero) indicates that
polling is disabled; a value
of
1
indicates that polling
is enabled.
3.
After completing steps 1 and
2, reboot the affected system.
4.
Repeat this procedure for
every server visible to tape
drives.
IMPORTANT:
Adding or removing tape drives
may cause an older driver .inf
file to be reread, which can
re-enable RSM polling. If tape
drives are added or removed,
check the registry for proper
configuration. If necessary,
repeat step 2 and 3 above.
To disable polling in the HP SDLT
driver (v3.0.2.0 or later):
1.
Open the Device Manager on
the server connected to the
tape drive.
2.
Double-click an SDLT tape
drive.
3.
Click the DLT tab.
4.
Check
Increase perform-
ance by disabling sup-
port for Microsoft
Backup Utility
.
Troubleshooting
228
Summary of Contents for StorageWorks 12000
Page 14: ...14 ...
Page 102: ...Operation 102 ...
Page 110: ...User Interfaces 110 ...
Page 150: ...Management 150 ...
Page 168: ...Monitoring 168 ...
Page 198: ...Component Identification 198 ...
Page 222: ...Support and Other Resources 222 ...
Page 232: ...Troubleshooting 232 ...
Page 236: ...Specifications 236 ...
Page 244: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 244 ...
Page 245: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 245 ...
Page 246: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 246 ...
Page 247: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 247 ...
Page 249: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 249 ...
Page 250: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 250 ...
Page 251: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 251 ...
Page 252: ...Spanish Battery Notice Regulatory Compliance Notices 252 ...