3.
Present the LUNs:
CAUTION:
Present only the disks that you wish to use with the VLS Gateway because existing data will
be destroyed during storage pool configuration.
a.
In Command View EVA, in the Storage tab navigation tree, select the EVA for the VLS
Gateway storage system,
Virtual Disks
, the disk name that you want to present, then
ACTIVE
under that disk.
b.
Select the
Presentation
tab.
c.
Ensure that
Write Protect
is set to
No
.
d.
Ensure that the
Preferred path/mode
is set to either
Path A-Failover only
or
Path B-Failover
only
(
Figure 11
).
NOTE:
Set the
Preferred path/mode
for half of the disks to
Path A-Failover only
, and to
Path B-Failover only
for the other half of the disks. This balances the data traffic across
both A and B controllers. For more information on data traffic balancing, see
“
Array Dual Pathing
” on page 144.
Figure 11 Vdisk Active Member Properties window
.
e.
Click on
Present
, then select the VLS Gateway host (just created) on the
Present Vdisk
screen
on the status pane.
f.
Click on
Present Vdisk
.
g.
The
Operation Succeeded
message displays on the status pane. Click
OK
.
h.
Repeat these steps for each disk to present to the VLS.
HP StorageWorks
39
Summary of Contents for StorageWorks 12000
Page 14: ...14 ...
Page 102: ...Operation 102 ...
Page 110: ...User Interfaces 110 ...
Page 150: ...Management 150 ...
Page 168: ...Monitoring 168 ...
Page 198: ...Component Identification 198 ...
Page 222: ...Support and Other Resources 222 ...
Page 232: ...Troubleshooting 232 ...
Page 236: ...Specifications 236 ...
Page 244: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 244 ...
Page 245: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 245 ...
Page 246: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 246 ...
Page 247: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 247 ...
Page 249: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 249 ...
Page 250: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 250 ...
Page 251: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 251 ...
Page 252: ...Spanish Battery Notice Regulatory Compliance Notices 252 ...