System Error Messages
116
Diagnostic and System Error Messages Version 3.1.x Reference Guide
Message
Probable Cause
The Fabric Assist (FA) zoning configuration has more than one initiator. The
probable cause is incorrect entries in the FA zoning configuration.
Recommended Action
Edit the zoning database. Make sure that only one initiator is set for each FA zone
configuration.
Severity
Error
Message
Probable Cause
An incorrect zoning enforcement type was reported on the specified port. This
indicates an error in the firmware.
Recommended Action
Copy the message and then contact Technical Support.
Severity
Error
ZONE-INCORRECT_FA_CONFIG
<switch number> Error ZONE-INCORRECT_FA_CONFIG, 2, FA Zone <zone name>
missing correct number of Initiator and Target devices
ZONE-INCORRECT_ENFORCEMENT
<switch number> Error ZONE-INCORRECT_ENFORCEMENT, 2, Incorrect zoning
enforcement type <zone type> at port <port number>