ZONE_System Error Messages
121
Diagnostic and System Error Messages Version 3.1.x Reference Guide
Severity
Warning
Message
Probable Cause
An unauthorized device is accessing the fabric. Zoning detected a discrepancy
between the frame and the information that the device registered with the Name
Server during PLOGI/ADISC/DISC trap processing. The discrepancy occurred
within the set of information that includes device PID, port WWN, and node
WWN. This is considered to be a security violation and the frame is dropped.
Recommended Action
Determine which device is accessing the port and disconnect it.
Severity
Error
Message
Probable Cause
A Zone Filter or Zone Group Check Failure occurred. The Frame Filter Logic
reported a failure when creating or adding zone groups during PLOGI trap
processing. This error should not occur. If it does, it is due to a programming error
caused by adding CAM entries before the filter setup.
ZONE-WWNSPOOF
<switch number> Error ZONE-WWNSPOOF, 2, WWN spoofing at (d,p)=(%d,%d)
PortWWN <WWN number> NodeWWN (%s,%s)
ZONE-WWNZONECHECK
<switch number> Error ZONE-WWNZONECHECK, 2, WWN zoneTypeCheck or
zoneGroupCheck failure(%s) at port (%d)