System Error Messages
40
Diagnostic and System Error Messages Version 3.1.x Reference Guide
FCP_System Error Messages
The Fibre Channel Protocol (FCP) application is responsible for probing the
devices attached on the loop port. The switch uses probing to identify the devices
attached on the loop ports and to update the Name Server with the information.
Message
Explanation
The FCP switch probes devices on the loop port; probing timed out on the
specified port for the specified ALPA (arbitrated loop physical address).
Port number values can be 0-15; the ALPA range is any value 00 - FF.
Recommended Action
Retry the action. If the error persists, contact Technical Support.
Severity
Warning
FCP-PROBE_TIMEOUT
<switch number> Warning FCP-PROBE_TIMEOUT, 3, AL_PA <ALPA address> on port
<port number> did not respond