FSPF_System Error Messages

47

Diagnostic and System Error Messages Version 3.1.x Reference Guide

Recommended Action

No action required.

Severity

Informational

Message

Explanation

The specified remote Domain ID is out of range.

Recommended Action

The frame will be discarded; no user action is required.

Severity

Error

Message

Explanation

An invalid Switch Change Notification (SCN) was reported for the specified port. 
The valid SCNs are 1 (on line), 2 (off line), 3 (testing), 4 (faulty), 5 (E_Port), 6 
(F_Port), 7 (segmented), and 8 (T_Port).

FSPF-REMDOMAIN

<switch number> Error FSPF-REMDOMAIN, 2, Remote Domain ID <domain number
out of range, input port = <port number>

FSPF-SCN

<switch number> Warning FSPF-SCN, 3, Illegal SCN, port <port number>, state 
<state code>

Summary of Contents for StorageWorks 16-EL - SAN Switch

Page 1: ... error messages version 3 1 x Product Version 3 1 x First Edition July 2003 Part Number AA RUPZA TE This reference guide lists Fabric OS diagnostic and system error messages The probable cause and recommended course of action is provided for each message ...

Page 2: ...slated into another language without the prior written consent of Hewlett Packard The information contained in this document is subject to change without notice UNIX is a registered trademark of The Open Group Hewlett Packard Company shall not be liable for technical or editorial errors or omissions contained herein The information is provided as is without warranty of any kind and is subject to c...

Page 3: ...Message Severity Levels 13 Overview of System Logs 15 System Error Log 16 Syslogd Daemon 16 Port Logs 17 System Console 17 View or Configure System Logs 17 Reading a System Error Message 19 Viewing System Error Messages from Advanced Web Tools 19 Displaying the Error Log without Page Breaks 19 Displaying the Error Log with Page Breaks 20 Clearing the Switch Error Log 21 Sample Error Log Message 21...

Page 4: ...ISABLE 31 ERRLOG NV_LOG_CLRD 32 ERRLOG NV_LOG_RESIZE 32 ERRLOG SET_MSG_SAVE_LVL 33 FABRIC_System Error Messages 34 FABRIC ASYNC 34 FABRIC NO_ALIASID 34 FABRIC SEGMENTED 35 FABRIC SIZE_EXCEEDED 35 FABRIC WEBTOOL_DISABLE 36 FABRIC WEBTOOL_LIFE 36 FCIU_System Error Messages 38 FCIU IUBAD 38 FCIU IUCOUNT 39 FCP_System Error Messages 40 FCP PROBE_TIMEOUT 40 FCPH_System Error Messages 41 FCPH EXCHBAD 41...

Page 5: ...m Error Messages 55 MCAST ADDBRANCH 55 MCAST ADDPORT 55 MCAST REMPORT 56 MPATH_System Error Messages 57 MPATH NOPARENT 57 MPATH NOPARENTLSR 57 MPATH UNREACHABLE 58 MQ_System Error Messages 59 MQ MSGTYPE 59 MQ QREAD 60 MQ QTHR 63 MQ QWRITE 64 MS_System Error Messages 65 MS INVALID_CTRESP 65 MS OUT_RESOURCES 66 MS PLDBSEG 66 MS PLSTATE 68 MS RCSFAILED 69 MS TIME_OUT 70 MS UNEXPECTED_IUDATASZ 70 MS U...

Page 6: ...Messages 81 RTWR FAILED 81 RTWR TRANSMIT 84 SEC_System Error Messages 85 SEC RSENDFAIL 85 SEC SECDBFAIL 86 SEC SECDLFAIL 86 SEC SECINFO 87 SEC SECINFORM 87 SEC SEC_STATS 88 SEC SECVIOL_API 89 SEC SECVIOL_HTTP 89 SEC SECVIOL_TELNET 90 SECLIB_System Error Messages 91 SECLIB SECVIOL_DCC 91 SECLIB SECVIOL_LOGIN_API 92 SECLIB SECVIOL_LOGIN_HTTP 92 SECLIB SECVIOL_LOGIN_MODEM 93 SECLIB SECVIOL_LOGIN_REMO...

Page 7: ...CK LOGIN 106 TRACK LOGOUT 107 TRACK TRACK_OFF 107 TRACK TRACK_ON 108 TS_System Error Messages 109 TS CLKSVRERR 109 TS NTPQFAIL 109 TS TSINFO 110 TS TS_SVR_ERRCODE_EXITS 111 TS TSSVREXITS 111 UCAST_System Error Messages 112 UCAST DOUBLEPATH 112 UPATH_System Error Messages 113 UPATH UNREACHABLE 113 ZONE_System Error Messages 114 ZONE DUPLICATE_ENTRY 114 ZONE ENFORCEMIX 115 ZONE INCORRECT_FA_CONFIG 1...

Page 8: ...3 Debug Level Messages 134 Index 137 Figures 1 Error log without page breaks 20 2 Error log with page breaks 21 3 Sample error log message 21 Tables 1 Text Conventions 10 2 Error Message Severity Levels 15 3 Commands to View or Configure System Logs 17 4 Error Message Field Description 22 5 Alphabetical List of Messages 123 6 Panic Level Error Messages 128 7 Critical Level Error Messages 129 8 Err...

Page 9: ...or use by systems administrators and technicians experienced with networking Fibre Channel and SAN technologies Related Documentation For a list of related documents included with this product see the Related Documents section of the Release Notes that came with this product For the latest information documentation and firmware releases visit the HP StorageWorks website http www hp com country us ...

Page 10: ...1 Text Symbols The following symbols may be found in the text of this guide They have the following meanings WARNING Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or death Table 1 Text Conventions Element Convention Cross reference links Blue text Figure 1 Key and field names menu items buttons and dialog box titles Bold File nam...

Page 11: ...ldwide technical support are listed on the HP website http www hp com support From this website select the country of origin Note For continuous quality improvement calls may be recorded or monitored Be sure to have the following information available before calling Technical support registration number if applicable Product serial numbers Product model names and numbers Applicable error messages ...

Page 12: ... Version 3 1 x Reference Guide HP Authorized Reseller For the name of your nearest HP authorized reseller In the United States call 1 800 345 1518 In Canada call 1 800 263 5868 Elsewhere see the HP website for locations and telephone numbers http www hp com ...

Page 13: ...e cause and more than one recommended course of action for any given message This document provides the most probable cause and recommends the typically most beneficial response This chapter provides an introduction to the error log system and consists of the following major topics Error Message Severity Levels on page 13 Overview of System Logs on page 15 View or Configure System Logs on page 17 ...

Page 14: ...If you have any questions collect the applicable data and then contact technical support for further clarification Telephone numbers for worldwide technical support are listed on the HP website http www hp com support From this website select the country of origin The severity levels are specified in Table 2 ...

Page 15: ...al Critical level messages indicate serious problems detected by the software that will eventually cause a partial or complete failure of a subsystem for example a power supply or sensor failure can generate a critical level error message Some critical errors may overlap in severity with panic level errors 2 Error Error level messages indicate conditions that may not be fatal These messages are co...

Page 16: ... and users specified by its configuration file Refer to the manual pages and related documentation for your particular UNIX host system for more information on the syslogd process and its capabilities The Fabric OS can be configured to use a UNIX style syslog daemon syslogd process to read system events and error messages and forward these messages to users and or write the events to log files on ...

Page 17: ...orageWorks Fabric OS Procedures Guide for information on interpreting the output from the portlogdump command Note The Port Log functionality is completely separate from the System Error Log functionality Typically Port Logs are used to troubleshoot connection of devices s System Console The system console displays messages through the serial port If you telnet into the Ethernet port you will not ...

Page 18: ...g facility portlogresize Resize the Port Log to the specified number of entries portlogshow Display the Port Log with page breaks portlogshowport Display the Port Log of the specified port with page breaks setdbg Set the level of debug messages reported by a particular module seterrlvl Set the level of errors reported by a particular module setverbose Set the verbose level of a particular module w...

Page 19: ...y Viewing System Error Messages from Advanced Web Tools To view the System Error Log for a switch from Advanced Web Tools 1 Launch Advanced Web Tools 2 Select the desired switch from the Fabric Tree The Switch View appears 3 Select the Switch Events button from the Switch View A Switch Events Report appears 4 View the switch events and messages Displaying the Error Log without Page Breaks To displ...

Page 20: ...the System Error Log An error log similar to that shown in Figure 2 displays switch admin errdump Error 04 0x76 fabos Mar 25 08 26 44 1 Switch 1 Info TRACK LOGIN 4 Successful login Error 03 0x576 fabos Mar 24 16 01L44 12 Switch 1 info TRACK CONFIG_CHANGE 4 Config file change from task ZNIPC Error 02 0x2f0 fabos Mar 24 15 07 01 Switch 1 Warning FW STATUS_SWITCH status changed from HEALTHY OK to Mar...

Page 21: ...the errclear command to clear the System Error Log Sample Error Log Message Figure 3 shows a typical message from the error log Figure 3 Sample error log message The fields in this error message are explained in Table 4 switch admin errshow Error 497 0x4a5 fabos Oct 03 04 40 14 Switch 0 Info TRACK LOGIN 4 Successful login Type CR to continue Q CR to stop q Error 1001 0x253 fabos Nov 03 14 11 53 Sw...

Page 22: ...he position of this error message in the buffer This number is not permanently affiliated with the error itself and should not be used when contacting Technical Support Nov 03 14 11 53 Date and time The date and time the error message occurred Switch 1 Switch number The logical switch that was affected number values are 0 and 1 Error Severity level The severity of the message as Panic Critical Err...

Page 23: ...or troubleshooting a system error message Note that all of the information collected here should be provided to Technical Support if you require troubleshooting assistance Run supportshow and pdshow and save the output Document the sequence of events leading up to the problem What actions did you take before the problem occurred Is the problem repeatable What configuration is required to produce t...

Page 24: ...1 x Reference Guide Common Responses The following are common responses to system error messages Run supportshow and pdshow and provide the output to Technical Support Gather logs Watch for reoccurrence Reinstall firmware Reboot the machine Revert to previous firmware version Call support ...

Page 25: ...m Error Messages on page 31 FABRIC_System Error Messages on page 34 FCIU_System Error Messages on page 38 FCP_System Error Messages on page 40 FCPH_System Error Messages on page 41 FLOOD_System Error Messages on page 44 FSPF_System Error Messages on page 46 HLO_System Error Messages on page 50 LSDB_System Error Messages on page 53 MCAST_System Error Messages on page 55 MPATH_System Error Messages ...

Page 26: ...e 113 ZONE_System Error Messages on page 114 AS_ System Error Messages Alias Server provides a multi casting capability a single frame can be delivered to multiple ports The user defines a group of ports identified by the Alias ID and delivers a frame to that group using the Alias ID The Alias Server daemon tracks the Alias ID Message Explanation Memory allocation failure Fabric OS error Recommend...

Page 27: ...ble and supportshow in order to capture debug information and then contact Technical Support Technical Support may also ask for additional debug information from POST and systemtest Severity Warning Message Explanation If the specified port was previously disabled because no buffer was available the port is now enabled because a buffer has been made available in the same quad BLOOM BAD_ID switch n...

Page 28: ...in order to capture debug information and then contact Technical Support Technical Support may also ask for additional debug information from POST and systemtest Severity Warning Message Explanation The specified port was disabled due to lack of available buffers This usually happens when one or more ports in the same quad are configured as long distance BLOOM MINI_BUFFER switch number Warning BLO...

Page 29: ...supportshow in order to capture debug information and then contact Technical Support Technical Support may also ask for additional debug information from POST and systemtest Severity Critical Message Explanation One of the following situations occurred when the port was busy transitioning to the next state on the specified slot and port BLOOM RAMINIT_TO switch number Critical BLOOM RAMINIT_TO 1 po...

Page 30: ...sition to the CLOSE state init stuck at bloomLPC waiting for OPEN state Explanation The specified port could not transition to the OPEN state when executing the Loop Port Control LPC command Recommended Action Copy the error message information run portlogdisable and supportshow in order to capture debug information and then contact Technical Support Technical Support may also ask for additional d...

Page 31: ...r messages in nonvolatile storage so the information can be retrieved and displayed later Message Explanation Informational message stating that the error log was cleared using the telnet command errclear Recommended Action No action required Severity Informational Message Explanation An informational message stating that the Persistent nonvolatile Error Log was disabled by the telnet command errn...

Page 32: ...tion required Severity Informational Message Explanation An informational message stating that the number of errors in the Persistent nonvolatile Error Log has been changed and can now store number of errors in log entries The default size is 1024 It can be resized to any value between 1024 and 2068 ERRLOG NV_LOG_CLRD switch number Info ERRLOG NV_LOG_CLRD 4 Persistent error log cleared ERRLOG NV_L...

Page 33: ...error messages will be saved The maximum number of persistent messages is 256 HP recommends that you always set the Persistent Error Log to record at least Panic errors level 0 and Critical errors level 1 If the log fills up more critical messages take precedence over less critical messages in the log The severity levels of error messages are 0 Panic 1 Critical 2 Error 3 Warning 4 Informational 5 ...

Page 34: ...ree throttling the trunking process and distributing the domain and alias list to all switches in the fabric Message Explanation The Information Unit response was invalid for the specified command sent Recommended Action Copy the error message and then call Technical Support Severity Warning Message Explanation The fabric does not have available multicast alias IDs to assign to the alias server FA...

Page 35: ...ded Action Verify that the specified port is segmented using the command switchshow Using information provided in description of segmentation correct the reason for segmentation Severity Warning Message Explanation There are too many switches in the fabric FABRIC SEGMENTED switch number Warning FABRIC SEGMENTED 3 port port number description of segmentation FABRIC SIZE_EXCEEDED switch number Criti...

Page 36: ...orted configuration Recommended Action Remove switches from the fabric until the fabric meets the supported configuration Web Tools will automatically be enabled Severity Critical Message Explanation If the fabric size exceeds the supported configuration then Web Tools will be disabled in the specified number of days hours and minutes FABRIC WEBTOOL_DISABLE switch number Critical FABRIC WEBTOOL_DI...

Page 37: ...ystem Error Messages 37 Diagnostic and System Error Messages Version 3 1 x Reference Guide Recommended Action Remove switches from the fabric until the fabric meets the supported configuration Severity Critical ...

Page 38: ...er provides a pointer to the IU causing the error message This error message can be caused by one of the following conditions NULL IU pointer NULL IU header pointer NULL IU data pointer or no IU data Size of the IU is larger than the memory allocation size Recommended Action Run the supportshow command to display the error message trace information that shows where the IU error message occurred Co...

Page 39: ...this return is an invalid action The IU Pointer provides a pointer to the IU causing the error message Recommended Action Run the supportshow command to find the error message trace information to learn where the IU error message occurred Copy the trace back information printed with this error Contact Technical Support with both sets of information Severity Critical FCIU IUCOUNT switch number Crit...

Page 40: ...rts and to update the Name Server with the information Message Explanation The FCP switch probes devices on the loop port probing timed out on the specified port for the specified ALPA arbitrated loop physical address Port number values can be 0 15 the ALPA range is any value 00 FF Recommended Action Retry the action If the error persists contact Technical Support Severity Warning FCP PROBE_TIMEOU...

Page 41: ... Fibre Channel responder ID Exchange Data3 The exchange status flags Exchange Data4 The physical port number Exchange Data5 The Fibre Channel class of service Exchange Data6 The receiver unsolicited registry index IU Pointer The pointer Information Unit IU Header0 The Fibre Channel routing control bits R _ and destination ID D format RRDDDDDD IU Header1 The Fibre Channel destination ID D and unuse...

Page 42: ...is provided in the error message Exchange Data0 The Fibre Channel header exchange ID for the Originator O and Responder R format OOOORRRR Exchange Data1 The Fibre Channel source ID Exchange Data2 The Fibre Channel responder ID Exchange Data3 The exchange status flags Exchange Data4 The physical port number Exchange Data5 The Fibre Channel class of service Exchange Data6 The receiver unsolicited re...

Page 43: ...n 3 1 x Reference Guide Recommended Action Run the supportshow command the error message trace information shows where the IU error message occurred Copy the trace back information printed with this error Contact Technical Support with both sets of information Severity Debug ...

Page 44: ...te Record LSR type is unknown The following two LSR header types are the only known types 1 for Unicast and 3 for Multicast Recommended Action The record will be discarded No user action is required Severity Warning Message Explanation The acceptable link count received was exceeded in the Link State Record FLOOD INVLSR switch number Warning FLOOD INVLSR 3 Unknown LSR type port port number type LS...

Page 45: ...FLOOD_System Error Messages 45 Diagnostic and System Error Messages Version 3 1 x Reference Guide Recommended Action The record will be discarded No user action is required Severity Warning ...

Page 46: ...pecified input port number is out of range it does not exist on the switch Recommended Action The frame will be discarded no user action is required Severity Error Message Explanation Wrong Domain ID from neighbor adjacent switch in the Hello message from the specified port This can occur when a Domain ID for a switch has been changed FSPF INPORT switch number Error FSPF INPORT 2 Input Port port n...

Page 47: ...be discarded no user action is required Severity Error Message Explanation An invalid Switch Change Notification SCN was reported for the specified port The valid SCNs are 1 on line 2 off line 3 testing 4 faulty 5 E_Port 6 F_Port 7 segmented and 8 T_Port FSPF REMDOMAIN switch number Error FSPF REMDOMAIN 2 Remote Domain ID domain number out of range input port port number FSPF SCN switch number War...

Page 48: ...cified input port HP supports only Section ID 0 zero Recommended Action Verify that the reported Section ID is 0 zero Severity Error Message Explanation The specified FSPF version is not supported on the specified input port FSPF SECTION switch number Error FSPF SECTION 2 Wrong Section Id section number should be 0 input port port number FSPF VERSION switch number Error FSPF VERSION 2 FSPF Version...

Page 49: ...FSPF_System Error Messages 49 Diagnostic and System Error Messages Version 3 1 x Reference Guide Recommended Action Update the FSPF version by loading the correct version of firmware Severity Error ...

Page 50: ...ies Message Explanation The HELLO message was incompatible The dead timeout value does not match the value specified in the FSPF protocol Since the dead timeout value is incompatible the local switch will not accept FSPF frames from the remote switch Recommended Action The dead timeout value of the remote switch must be made compatible with the value specified in the FSPF protocol See the manufact...

Page 51: ...on The HELLO timeout value of the remote switch must be made compatible with the value specified in the FSPF protocol See the manufacturer s documentation to change this value Severity Error Message Explanation The HELLO message received from the specified local port domain ID and remote port ID was reported to be invalid HLO HLOTIMEOUT switch number Error HLO HLOTIMEOUT 2 Incompatible Hello timeo...

Page 52: ...he remote switch is incompatible with the local switch the local switch will not accept FSPF frames from the remote switch The HELLO message of the remote switch must be made compatible with the value specified in the FSPF protocol See the manufacturer s documentation to change this value Call Technical Support with questions Severity Error ...

Page 53: ...is out of the acceptable range Recommended Action This record will be discarded No user action is required Severity Error Message Explanation The local Link State Database reached the maximum number of incarnations Recommended Action No action required The incarnation number will wrap around Severity Informational LSDB LSID switch number Error LSDB LSID 2 Link State ID link state ID out of range L...

Page 54: ... disable and enable Severity Critical Message Explanation There is no Link State Database record for the specified local domain Recommended Action Perform a switch disable and enable Severity Warning LSDB NOLOCALENTRY switch number Critical LSDB NOLOCALENTRY 1 No database entry for local Link State Record domain local domain LSDB NOLSR switch number Warning LSDB NOLSR 3 No Link State Record for do...

Page 55: ...add branch failed to build up a tree like connectivity between ISL ports from a specified MCAST group Recommended Action Perform a port disable and enable on port port number Severity Error Message Explanation The add port failed to configure a port to be a member of a specified MCAST group MCAST ADDBRANCH switch number Error MCAST ADDBRANCH 2 Add branch failed Mcast Grp group number Port port num...

Page 56: ...0 through 254 Severity Warning Message Explanation The Remove Port failed to cancel the membership of a specified MCAST group for a port Recommended Action Verify that the MCAST group ID is valid 0 through 254 Severity Warning MCAST REMPORT switch number Warning MCAST REMPORT 3 Remove port failed Mcast Grp group number Src port number Dest port number ...

Page 57: ...ee structure in which the parent is used to connect to the root of the tree Recommended Action No user action required Call Technical Support if the error persists Severity Error Message Explanation The Link State Record is null Recommended Action No action required If the error is not persistent it is not a problem Severity Error MPATH NOPARENT switch number Error MPATH NOPARENT 2 Null parent lsI...

Page 58: ... Guide Message Explanation No minimum cost path FSPF MPath is available in the candidate list the candidate list is customer defined Recommended Action No action required Severity Warning MPATH UNREACHABLE switch number Warning MPATH UNREACHABLE 3 No minimum cost path in candidate list ...

Page 59: ...ocess can read messages from a message queue Message Explanation An unexpected message has been received in the specified message queue The message queue name and the type of the message are indicated in the message The following variables can be displayed in the error message queue name err_q fspf_q restart_q queue ID message type 0MSG_IU 1MSG_SCN 2MSG_TX 3MSG_INTR 4MSG_STR 5MSG_TO 6MSG_ASYNC_IU ...

Page 60: ...pport Severity Error Message Explanation A read from the specified message queue was unsuccessful because there were no messages immediately available read with no wait or because the message occurred after some timeout period read with timeout The name of the message queue and the queue ID are indicated in this error log message The following variables can be displayed in the error message queue ...

Page 61: ...ges Version 3 1 x Reference Guide fspf_q qloop_q RDTS_q zone_realtime_q zone_q restart_q embSW_q pb_q fcp_q rt_q apims_q ms_q msAsync_q ms2ns_q ns_q nsirc_q tns_q nscam_q restart_q timer_q response_q receive_q transmit_q scn_q smb_q snmp_agt_q famib_q fru_q ts_q ...

Page 62: ...3MSG_INTR 4MSG_STR 5MSG_TO 6MSG_ASYNC_IU 7MSG_LINIT_IU 8MSG_RSCN 9MSG_IOCTL 10MSG_ACCEPT 11MSG_IU_FREE 12MSG_US 13MSG_EXT_RSCN 14MSG_RDTS_START 15MSG_RDTS_SENDEFP 16MSG_RDTS_RESET Recommended Action Run the mqshowall command and record the output Provide both the mqshowall output and the error message to Technical Support Severity Critical ...

Page 63: ...message queue the queue ID and the number of messages currently in the queue are provided in this error log message See the MQ READ message description for a list of variables that can be displayed in this error message Recommended Action Run the mqshowall command and record the output Provide both the mqshowall output and the error message to Technical Support Severity Debug MQ QTHR switch number...

Page 64: ...ID and the error number are provided in the error log message See the MQ QREAD message for the list of variables that can be displayed in this error message Recommended Action Run the mqshowall command and record the output Provide both the mqshowall output and the error message to Technical Support Severity Critical MQ QWRITE switch number Critical MQ QWRITE 1 mqWrite queue queue name queue ID qu...

Page 65: ...Unzoned Name Server provides access to Name Server information that is not subject to Zone constraints The Fabric Zone Server provides access to and control of Zone information Message Explanation The MS received an invalid Common Transport CT response from domain The MS expects either a CT accept Information Unit IU or a reject IU The MS received neither response which violates the Fibre Channel ...

Page 66: ...Action The switch may be temporarily busy and out of resources to respond to a request If the error occurs frequently check the available memory on the switch using memshow and then contact Technical Support Severity Error Message Explanation The Management Server MS has segmented from another switch domain at the specified port port number due to errors or inconsistencies defined in the MS Platfo...

Page 67: ...abases between the switches Recommended Action Ensure mergeability of connecting fabrics For example some DB objects may have conflicting definitions Issue the command msplatshow to show content of DB and check for conflicts EXGPLDB failed DB size exceeds limit Explanation Exchange of Platform Service database between fabrics has failed due to the violation of the size allowance for the MS Platfor...

Page 68: ... MS Platform Service is unstable The following variables can be displayed function code invoking error capmat msPlCapMatrix CA msPlCondActivate message string No Resp for GCAP from Explanation Switch did not respond to a request for GCAP MS Get Capabilities command Recommended Action No user action required GCAP sup but not PL by Explanation GCAP MS Get Capabilities is supported but the flag for M...

Page 69: ...hat caused the error It is unique to the fabric Recommended Action See individual message string in Explanation above Severity Debug Message Explanation Usage of the Reliable Commit Service RCS has failed in MS The specified Management Server MS Command Transport command command for an RCS request failed for the specified RCS reason code and is described in more detail in the RCS reason code strin...

Page 70: ...etry the request If error recurs contact Technical Support Severity Error Message Explanation The Management Server MS received Information Unit IU data of unexpected size The IU payload and the IU size may be inconsistent with each other or with the command that is currently being processed Recommended Action Retry the operation If the error recurs contact Technical Support MS TIME_OUT switch num...

Page 71: ... Message Explanation The Management Server MS detected an unstable fabric the command or operation may not be successfully completed The following elements appear in the message function code invoking error MsgPlatDBProc msPlatMsgPlatDBProc MsgGCAP msPlatMsgGCAP MsgPl D ACTV MsPlayMsgActivateProc MS UNSTABLE_DCOUNT switch number Debug MS UNSTABLE_DCOUNT 5 MS detected ONLY 1 Domain domain in local ...

Page 72: ... for a req from Explanation Domain is invalid for a request No WWN for Explanation Unable to acquire the World Wide Name for corresponding domain domain number Explanation Target domain that caused error Unique to the fabric Recommended Action Copy the error message string and then contact Technical Support Severity Debug ...

Page 73: ... on specific events For example when two switches are connected to each other using an ISL interswitch link cable they will be in the Init State After both switches receive HELLO messages they move to the Database Exchange State and so on NBFSM states are Down 0 Init 1 Database Exchange 2 Database Acknowledge Wait 3 Database Wait 4 and Full 5 Message Explanation A duplicate E_Port State Change Num...

Page 74: ...age Explanation From the current state the database transmit set flag was not set for the specified input state on the specified port Recommended Action No user action required Severity Warning NBFSM NGBRSTATE switch number Error NBFSM NGBRSTATE 2 Wrong input state name to neighbor FSM state current state name port port number NBFSM XMITFLAG switch number Warning NBFSM XMITFLAG 3 DB_XMIT_SET flag ...

Page 75: ...n file is the file name line is the line number and function is the function name The arguments 1 2 3 provide additional information about this assertion Recommended Action Run the supportshow command copy the error message output and send both to Technical Support Severity Error Message Explanation The switch failed memory allocation The information provided in argument 1 describes where in the c...

Page 76: ...ut and the error message and send both to Technical Support Severity Error Message Explanation The Performance Server daemon failed to create a PSD task The variable argument 1 provides details about this failure Recommended Action Run the supportshow command and then contact Technical Support Severity Error PS TASKCREATE switch number Error PS TASKCREATE 2 PS taskCreate failed to create task argu...

Page 77: ... tasks Message Explanation An authentication error was reported The specified address client IP address has bad credentials Recommended Action Enter the correct root admin or user name and password pair from the Fabric Access API host Severity Warning RAPID AUTH_ERR switch number Warning RAPID AUTH_ERR 3 Authentication Error client IP address has bad credentials bad user name and password pair ...

Page 78: ...lication is not registered with RCS then RCS returns this error Recommended Action Collect application name information provided in the message and call Technical Support Severity Error Message Explanation The specified application on another switch rejected this RCS transaction with the specified reject reason RCS then returns this error and aborts the current transaction The current state descri...

Page 79: ... data is correct collect information provided in the error message and call Technical Support Severity Informational Message Explanation The RCS feature has been enabled Recommended Action None required Severity Debug Message Explanation Memory has not been allocated The specified RCS function failed to allocate memory RCS RCSENABLED switch number Debug RCS RCSENABLED 5 RCS has been enabled RCS RC...

Page 80: ...echnical Support Severity Error Message Explanation The RCS feature has been disabled on the local switch because not all switches in the fabric support RCS Currently versions 2 6 3 1 and 4 1 support the RCS feature Recommended Action Upgrade firmware to support RCS Severity Debug RCS RCSDISABLED switch number Debug RCS RCSDISABLED 5 RCS has been disabled Some switches in the fabric do not support...

Page 81: ...nical Support isolate the problem The error message can display any of the following details rtwrInit No Memory 0x9abc 0x8def 100 50 123 Explanation RTWR has run out of memory inside the rtwrInit function detail 1 if non zero contains the pointer of the payload received detail 2 if non zero contains the switch ID of the destination domain detail 3 if non zero contains the size of memory you should...

Page 82: ...n Check the memory usage on the switch or call Technical Support rtwrSyncRequest 0 0 0 0 0 Explanation Internal error Recommended Action Call Technical Support rtwrSyncRequest Unreachable domain 0xff domain 0x9abc domain 0xff Explanation Domain is not reachable Recommended Action Use fabricshow to see if the domain is offline Check the physical ISLs for the domain rtwrSyncRequest Cannot create syn...

Page 83: ...0 0xff 0xff 0xff Explanation Invalid pointer to payload Recommended Action Call Technical Support rtwrRespProcess Explanation Internal error Recommended Action Call Technical Support rtwrRespProcess realease_kiu failed 0 0 Explanation Internal error Recommended Action Call Technical Support rtwrRespProcess no such state 0 0 0 0 0 Explanation Internal error Recommended Action Call Technical Support...

Page 84: ...s error message RTWR Transmit maximum retries exhausted detail 1 Port detail 2 Domain detail 3 Retry Count detail 4 Status detail 5 Process ID Recommended Action Using the fabricshow command determine whether the specified Domain ID is offline Call Technical Support if the error persists Severity Warning RTWR TRANSMIT switch number warning RTWR TRANSMIT 3 RTWR error message detail 1 detail 2 detai...

Page 85: ...process failed to complete RCS is a reliable mechanism to transfer data from one switch to the other switches within the fabric This mechanism guarantees that either all switches update to the new database or none of them update to the new database This process can fail if one switch in the fabric is either busy or in an error state that cannot accept the database Recommended Action RCS is used wh...

Page 86: ...how command to verify that the fabric is still consistent All the switches should be in the Ready state If a switch is in the Error state the database may not be correctly updated for that specific switch Follow the standard recovery process The error may also be a result of an internal corruption or a hacker attack to the secure fabric Severity Warning Message Explanation The specified domain num...

Page 87: ...e switch has an unexpected error such as low memory queue full failure to set password or failure to set SNMP string Recommended Action Depending on the information in the message you should check the status of the switch and then retry the process or command If the problem persists contact Technical Support Severity Informational Message SEC SECINFO switch number Info SEC SECINFO 4 s SEC SECINFOR...

Page 88: ... secfabricshow to verify that the fabric is not being attacked by unauthorized users Severity Informational Message Explanation The switch logs each error for any statistic related security command secstatsshow secstatsreset to keep track of any security violations on the switch The counter is updated automatically when a security violation occurs This message may also occur if the updating counte...

Page 89: ...h through an API connection Take appropriate action Severity Informational Message Explanation A security violation was reported The specified unauthorized host attempted to establish an HTTP connection SEC SECVIOL_API switch number Info SEC SECVIOL_API 4 Security violation Unauthorized host with IP address IP address tries to establish API connection SEC SECVIOL_HTTP switch number Info SEC SECVIO...

Page 90: ...they should be accessing the switch then add the host to the security database so that it is authorized Severity Informational Message Explanation A security violation was reported The specified unauthorized host attempted to establish a Telnet connection Recommended Action Check to see whether an unauthorized host is accessing the switch through an API connection Take appropriate action Severity ...

Page 91: ...ssage Explanation A security violation was reported The specified unauthorized device attempted to flogin to the specified port and switch Recommended Action Check DCC policy and verify that the specified device is allowed in the fabric and is included in the DCC policy If the specified device is not included in the policy add it to the policy If the device is not allowed this is a valid violation...

Page 92: ...st is not allowed in the fabric this is a valid violation message and an unauthorized entity is trying to access the fabric Appropriate action should be taken as specified by your enterprise security policy Severity Informational Message Explanation A security violation was reported The specified unauthorized device attempted to log in through an HTTP connection the login failed SECLIB SECVIOL_LOG...

Page 93: ...ation was reported An unauthorized device attempted to log in through a modem connection the login failed Recommended Action Check the serial policy and verify that the connection is allowed If the connection is allowed but not specified allow connection from the serial policy If your serial policy does not allow connection this is a valid violation message and an unauthorized entity is trying to ...

Page 94: ...the Telnet policy If the host is allowed access to the fabric but is not included in the Telnet policy add it to the policy If the host is not allowed access to the fabric this is a valid violation message and an unauthorized entity is trying to access the fabric Appropriate action should be taken as specified by your enterprise security policy Note Telnet Policy controls access for both Telnet an...

Page 95: ...not specified allow connection from serial policy If the serial policy does not allow connection this is a valid violation message and an unauthorized entity is trying to access the fabric Appropriate action should be taken as specified by your enterprise security policy Note The serial policy controls both modem and serial access so enabling access in serial policy will enable both modem and seri...

Page 96: ...ion is allowed If the connection is allowed but not specified allow connection in the MS policy If the MS policy does not allow connection this is a valid violation message and an unauthorized entity is trying to access the fabric Appropriate action should be taken as specified by your enterprise security policy Severity Informational SECLIB SECVIOL_MSaccess switch number Info ECLIB SECVIOL_MSacce...

Page 97: ...ty Informational Message Explanation A security violation was reported A Management Server device is operating on a non primary Fibre Channel switch Recommended Action No action required Severity Informational SECLIB SECVIOL_MSfwrd switch number Info SECLIB SECVIOL_MSfwrd 4 Security violation MS command is forwarded from non primary FCS switch SECLIB SECVIOL_MSop switch number Info SECLIB SECVIOL_...

Page 98: ...ost to the policy If the host is not allowed access to the fabric this is a valid violation message and an unauthorized entity is trying to access the fabric Appropriate action should be taken as specified by your enterprise security policy Severity Informational Message Explanation A security violation was reported The specified unauthorized switch attempted to join the secure fabric SECLIB SECVI...

Page 99: ...rity policy Severity Informational Message Explanation A security violation was reported The specified unauthorized host attempted to perform a write SNMP operation WSNMP Recommended Action Check the WSNMP policy and verify which hosts are allowed access to the fabric through SNMP If the host is allowed access to the fabric but is not included in the policy add the host to the policy If the host i...

Page 100: ...ons for the SAN Message Probable Cause The certificate on a port could not be verified against the root certificate Recommended Action A switch is trying to join a fabric and its certificate is not valid This could be someone trying to get into the fabric who is not allowed If it is a switch that should be allowed acquire a certificate for it If it should not be allowed the switch should be discon...

Page 101: ...P daemon failed to initialize the security library Recommended Action The SLAP daemon did not start because the library initialization failed Reboot the switch and see if the problem persists If the problem persists after reboot call HP Technical Support Severity Warning Message Probable Cause The signature of a received challenge could not be verified SLAP_SECPOLICYINIT switch number Error SLAP S...

Page 102: ... it to the security database Severity Warning Message Probable Cause The certificate received from a switch does not have the WWN of that switch Recommended Action Determine whether the certificate WWN matches the switch WWN If not the switch sending the switch certificate could be a rogue switch or its certificate could be corrupt If the switch is not authorized delete it If it is authorized then...

Page 103: ...ed to flogin to the specified secure port Recommended Action Check the security policy to verify that the device is allowed in the fabric If the device is allowed add it to security policy and connect to the appropriate port If the device is not allowed this is a valid security violation notification and appropriate action should be taken as specified in your enterprise security policy Severity In...

Page 104: ...tion on the Track Change feature and SNMP traps see the HP StorageWorks Fabric OS Reference Guide For information on configuring the Track Change feature refer to the HP StorageWorks Fabric OS Reference Guide or the HP StorageWorks Fabric OS Procedures Guide Message Explanation The switch configuration has changed from the specified task The following variables are displayed in the error message s...

Page 105: ... Reference Guide tPBmenu tPortmapd tFabric tFspf tRt tQL tFcph tRTZone tZone tFcp tNSd tASd tNSCAM tMSd tRapid tSnmpd tHttpD tRan tRanscn tMsApi tThad tFaScn tThFru Recommended Action No action required To see the new configuration issue the configshow command Severity Informational ...

Page 106: ...user name or password is wrong Recommended Action Verify that the user name and password are correct Severity Informational Message Explanation The specified switch reported a successful login Recommended Action No action required Severity Informational TRACK FAILED_LOGIN switch number Info TRACK FAILED_LOGIN 4 Unsuccessful login TRACK LOGIN switch number Info TRACK LOGIN 4 Successful login ...

Page 107: ...rmational Message Explanation The Track Change feature has been turned off using the Telnet command trackchangesset Recommended Action No action required Refer to the HP StorageWorks Fabric OS Procedures Guide to learn how to turn the Track Change feature back on Severity Informational TRACK LOGOUT switch number Info TRACK LOGOUT 4 Successful logout TRACK TRACK_OFF switch number Info TRACK TRACK_O...

Page 108: ...e Track Change feature has been turned on using the Telnet command trackchangesset Recommended Action No action required Refer to the HP StorageWorks Fabric OS Procedures Guide to learn how to turn the Track Change feature off Severity Informational TRACK TRACK_ON switch number Info TRACK TRACK_ON 4 Track changes on ...

Page 109: ... when the local clock was specified Recommended Action Verify that the clock server specified in the fabric is valid and correct If not configure the fabric with a valid clock server local clock or external NTP server IP address using the tsclockserver command Severity Warning Message Explanation The NTP query to the external clock server failed The local clock LOCL will be used as the clock serve...

Page 110: ...ailable If the specified clock server is not available point to an available server using the tsclockserver command Network problems may have caused a temporary error if the error does not recur it may be ignored Severity Warning Message Explanation Informational log Recommended Action No action required Severity Informational TS TSINFO switch number Info TS TSINFO 4 info message ...

Page 111: ...h User s Guide AA RTSGC TE for more information Severity Warning Message Explanation The Time Server is exiting The reason is specified in the message Recommended Action See Fabric Watch User s Guide AA RTSGC TE for more information Severity Warning TS TS_SVR_ERRCODE_EXITS switch number Warning TS TS_SVR_ERRCODE_EXITS 3 reason error code TS Server Exiting TS TSSVREXITS switch number Warning TS TSS...

Page 112: ... routing table Message Explanation Duplicate paths were reported to the specified domain from the specified output port The path database PDB pointer is the address of the path database and provides debugging information Recommended Action No user action required Severity Debug UCAST DOUBLEPATH switch number Debug UCAST DOUBLEPATH 5 Duplicate Path to Domain domain ID Output Port port number PDB po...

Page 113: ...PF algorithm to dynamically compute a Unicast tree Message Explanation The specified switch switch number is unreachable because no minimum cost path FSPF UPATH exists in the candidate list domain ID list Recommended Action This will end the current SPF computation No user action is required Severity Warning UPATH UNREACHABLE switch number Warning UPATH UNREACHABLE 3 No minimum cost path in candid...

Page 114: ...nnected devices Devices can also belong to more than one zone Because zone members can access only other members of the same zone a device not included in a zone is not available to members of that zone When zoning is enabled all devices must be zoned to communicate with the fabric These error messages indicate any problems associated with zoning Message Probable Cause Duplicate entries exist in t...

Page 115: ...lowing is detected A port zone member is also listed as a member of a MIXED zone A WWN zone member is also specified as a member of a MIXED zone Recommended Action If hardware zoning enforcement is preferred edit the zoning database to have the port zoned with devices defined as WWN or defined as Port Domain Severity Warning ZONE ENFORCEMIX switch number Warning ZONE ENFORCEMIX 3 WARNING HARD SOFT...

Page 116: ...each FA zone configuration Severity Error Message Probable Cause An incorrect zoning enforcement type was reported on the specified port This indicates an error in the firmware Recommended Action Copy the message and then contact Technical Support Severity Error ZONE INCORRECT_FA_CONFIG switch number Error ZONE INCORRECT_FA_CONFIG 2 FA Zone zone name missing correct number of Initiator and Target ...

Page 117: ...erity Error Message Probable Cause Frame Filter Logic reported a failure during one of the IOCTL calls The IOCTL call from which the failure is reported is listed as part of the error message If this error occurs it is due to a programming error caused by adding CAM entries before the filter setup Recommended Action Copy the error message and then contact Technical Support Severity Error ZONE INSU...

Page 118: ...t is targeted for the local switch contains a non existent port The effective zoning configuration displayed in the error message contains a port number that is out of range Recommended Action Edit the zoning database by changing the port number Severity Warning ZONE NOLICENSE switch number Error ZONE NOLICENSE 2 Missing required license license name ZONE PORT_OUT_OF_RANGE switch number Warning ZO...

Page 119: ...uide If you exceed the maximum number of entries that the hardware can handle zoning reverts to soft zoning and the switch and the SAN continue to run but the hardware can no longer prevent transfers that try to go to ports in the zones associated with the ports Recommended Action There are several possible explanations for this message including the following errors ZONE ZONEGROUPADDFAIL ZONE WWN...

Page 120: ...t it failed Recommended Action Collect the error information and then contact Technical Support Severity Error Message Probable Cause One or more devices are zoned as WWN with WWN devices and are also zoned as Port Domain with Port Domain devices The devices are used to specify zone members over separate zones Recommended Action If you prefer hardware zoning enforcement edit the zoning database to...

Page 121: ... a security violation and the frame is dropped Recommended Action Determine which device is accessing the port and disconnect it Severity Error Message Probable Cause A Zone Filter or Zone Group Check Failure occurred The Frame Filter Logic reported a failure when creating or adding zone groups during PLOGI trap processing This error should not occur If it does it is due to a programming error cau...

Page 122: ...ber of entries of SID CAM for the quad exceeded 64 while creating or adding a zone group The maximum number of CAM entities allowed for hardware zoning enforcement is 64 Recommended Action If you prefer hardware zoning enforcement edit the zoning database to have fewer zoned PIDs for that port Severity Warning ZONE ZONEGROUPADDFAIL switch number Warning ZONE ZONEGROUPADDFAIL 3 WARNING port port nu...

Page 123: ...ntains all of the version 3 1 x diagnostic and system error messages in alphabetical order To locate the description of a message in Chapter 2 activate the link to the message from column 1 below Table 5 Alphabetical List of Messages Message Severity AS CTMALLOC 2 Error BLOOM BAD_ID 3 Warning BLOOM BUF_RECLAIMED 4 Informational BLOOM MINI_BUFFER 3 Warning BLOOM NO_BUFFERS 3 Warning BLOOM RAMINIT_T...

Page 124: ... FCPH EXCHBAD 1 Critical FCPH EXCHFREE 5 Debug FCP PROBE_TIMEOUT 3 Warning FLOOD INVLSR 3 Warning FLOOD LINKCNT 3 Warning FSPF INPORT 2 Error FSPF NBRCHANGE 4 Informational FSPF REMDOMAIN 2 Error FSPF SCN 3 Warning FSPF SECTION 2 Error FSPF VERSION 2 Error HLO DEADTIMEOUT 2 Error HLO HLOTIMEOUT 2 Error HLO INVHLO 2 Error LSDB LSID 2 Error LSDB MAXINCARN 4 Informational LSDB NOLOCALENTRY 1 Critical...

Page 125: ...MS INVALID_CTRESP 2 Error MS OUT_RESOURCES 2 Error MS PLDBSEG 3 Warning MS PLSTATE 5 Debug MS RCSFAILED 5 Debug MS TIME_OUT 2 Error MS UNEXPECTED_IUDATASZ 2 Error MS UNSTABLE_DCOUNT 5 Debug MS UNSTABLE_FABRIC 5 Debug NBFSM DUPEPORTSCN 5 Debug NBFSM NGBRSTATE 2 Error NBFSM XMITFLAG 3 Warning PS ASSERT 2 Error PS MALLOC 2 Error PS TASKCREATE 2 Error RAPID AUTH_ERR 3 Warning RCS APP_NOTREG 2 Error RC...

Page 126: ... SECLIB SECVIOL_LOGIN_SERIAL 4 Informational SECLIB SECVIOL_MSaccess 4 Informational SECLIB SECVIOL_MSfwrd 4 Informational SECLIB SECVIOL_MSop 4 Informational SECLIB SECVIOL_RSNMP 4 Informational SECLIB SECVIOL_SCC 4 Informational SECLIB SECVIOL_WSNMP 4 Informational SEC RSENDFAIL 2 Error SEC SEC_STATS 3 Warning SEC SECDBFAIL 3 Warning SEC SECDLFAIL 2 Error SEC SECINFO 4 Informational SEC SECINFOR...

Page 127: ...CK TRACK_OFF 4 Informational TRACK TRACK_ON 4 Informational TS CLKSVRERR 4 Informational TS NTPQFAIL 3 Warning TS TS_SVR_ERRCODE_EXITS 3 Warning TS TSINFO 4 Informational TS TSSVREXITS 3 Warning UCAST DOUBLEPATH 5 Debug UPATH UNREACHABLE 3 Warning ZONE DUPLICATE_ENTRY 3 Warning ZONE ENFORCEMIX 3 Warning ZONE INCORRECT_ENFORCEMENT 2 Error ZONE INCORRECT_FA_CONFIG 2 Error ZONE INSUFF_PID_COUNT 2 Err...

Page 128: ...the description of a message in Chapter 2 activate the link to the message from the table Critical Level Messages Critical level messages indicate serious problems detected by the software that will eventually cause a partial or complete failure of a subsystem for example a power supply or sensor failure can generate a critical level error message Some critical errors may overlap in severity with ...

Page 129: ...rations after retries invalid parameters or failure to perform a requested operation Table 8 lists the Error level messages To locate the description of a message in Chapter 2 activate the link to the message from the table Table 7 Critical Level Error Messages Message BLOOM RAMINIT_TO FABRIC SIZE_EXCEEDED FABRIC WEBTOOL_DISABLE FABRIC WEBTOOL_LIFE FCIU IUCOUNT FCPH EXCHBAD LSDB NOLOCALENTRY MQ QR...

Page 130: ...SP MS OUT_RESOURCES MS TIME_OUT MS UNEXPECTED_IUDATASZ NBFSM NGBRSTATE PS ASSERT PS MALLOC PS TASKCREATE RCS APP_NOTREG RCS RCSENOMEM RTWR FAILED SEC SEC_STATS SEC SECDLFAIL ZONE INCORRECT_ENFORCEMENT ZONE INCORRECT_FA_CONFIG ZONE INSUFF_PID_COUNT ZONE IOCTLFAIL ZONE NOLICENSE ZONE TRANSCOMMIT ZONE WWNSPOOF ZONE WWNZONECHECK Table 8 Error Level Error Messages Continued Message ...

Page 131: ...threshold value Table 9 lists the Warning level error messages To locate the description of a message in Chapter 2 activate the link to the message from the table Table 9 Warning Level Error Messages Message BLOOM BAD_ID BLOOM MINI_BUFFER BLOOM NO_BUFFERS FABRIC ASYNC FABRIC NO_ALIASID FABRIC SEGMENTED FCP PROBE_TIMEOUT FLOOD INVLSR FLOOD LINKCNT FSPF SCN LSDB NOLSR MCAST ADDPORT MCAST REMPORT MPA...

Page 132: ... SLAP_SECPOLICYINIT SLAP_SIGNCHECKFAIL SLAP_WWNCHECKFAIL TS NTPQFAIL TS TS_SVR_ERRCODE_EXITS TS TSSVREXITS UPATH UNREACHABLE ZONE DUPLICATE_ENTRY ZONE ENFORCEMIX ZONE PORT_OUT_OF_RANGE ZONE SOFTZONING ZONE WWNINPORT ZONE ZONEGROUPADDFAIL Table 9 Warning Level Error Messages Continued Message ...

Page 133: ...ocate the description of a message in Chapter 2 activate the link to the message from the table Table 10 Informational Level Messages Message BLOOM BUF_RECLAIMED ERRLOG LOGCLRD ERRLOG NV_DISABLE ERRLOG NV_LOG_CLRD ERRLOG NV_LOG_RESIZE ERRLOG SET_MSG_SAVE_LVL FSPF NBRCHANGE LSDB MAXINCARN RCS LOCAL_REJECT SECLIB SECVIOL_DCC SECLIB SECVIOL_LOGIN_API SECLIB SECVIOL_LOGIN_HTTP SECLIB SECVIOL_LOGIN_MOD...

Page 134: ...ption of a message in Chapter 2 activate the link to the message from the table SEC SECINFORM SEC SECVIOL_API SEC SECVIOL_HTTP SEC SECVIOL_TELNET SWITCH SECVIOL_DCC TRACK CONFIG_CHANGE TRACK FAILED_LOGIN TRACK LOGIN TRACK LOGOUT TRACK TRACK_OFF TRACK TRACK_ON TS CLKSVRERR TS TSINFO Table 10 Informational Level Messages Continued Message Table 11 Debug Level Messages Message FCIU IUBAD FCPH EXCHFRE...

Page 135: ...ror Message Tables 135 Diagnostic and System Error Messages Version 3 1 x Reference Guide NBFSM DUPEPORTSCN RCS RCSDISABLED RCS RCSENABLED UCAST DOUBLEPATH Table 11 Debug Level Messages Continued Message ...

Page 136: ...Error Message Tables 136 Diagnostic and System Error Messages Version 3 1 x Reference Guide ...

Page 137: ... 88 secstatsshow 88 secversionreset 85 supportshow 23 24 27 28 29 30 38 39 42 43 75 76 switchshow 35 systemtest 30 trackchangesset 107 108 tsclockserver 109 110 configshow command 105 conventions document 10 equipment symbols 11 text symbols 10 critical level messages 15 128 D database exchange state 73 database transmit set flag 74 databases link state 44 53 54 MS platform 67 path 112 platform se...

Page 138: ...ort 11 worldwide technical support 14 I informational level messages 15 133 L link state database LSDB 44 53 54 link state record 44 54 57 Linux operating system 16 local clock LOCL 109 LSDB link state database 44 53 54 M management server command 97 messages AS CTMALLOC 26 BLOOM BAD_ID 27 BLOOM BUF_RECLAIMED 27 BLOOM MINI_BUFFER 28 BLOOM NO_BUFFERS 28 BLOOM RAMINIT_TO 29 BLOOM STUCK_WAIT 29 ERRLO...

Page 139: ...ECLIB SECVIOL_LOGIN_API 92 SECLIB SECVIOL_LOGIN_HTTP 92 SECLIB SECVIOL_LOGIN_MODEM 93 SECLIB SECVIOL_LOGIN_REMOTE 94 SECLIB SECVIOL_LOGIN_SERIAL 95 SECLIB SECVIOL_MSaccess 96 SECLIB SECVIOL_MSfwrd 97 SECLIB SECVIOL_MSop 97 SECLIB SECVIOL_RSNMP 98 SECLIB SECVIOL_SCC 98 SECLIB SECVIOL_WSNMP 99 SEC RSENDFAIL 85 SEC SEC_STATS 88 SEC SECDBFAIL 86 SEC SECDLFAIL 86 SEC SECINFO 87 SEC SECINFORM 87 SEC SEC...

Page 140: ... commit service RCS 69 78 85 reliable transport write and read RTWR 81 remote API daemon RAPID 77 RTWR reliable transport write and read 81 S SCC switch connection control 91 secfabricshow command 86 88 SECLIB security library 91 secpolicyactivate command 85 secpolicysave command 85 secstatsreset command 88 secstatsshow command 88 security database 85 security library SECLIB 91 secversionreset com...

Page 141: ...cast tree 113 UNIX operating system 16 unzoned name server 65 W warning rack stability 11 symbols on equipment 11 warning level messages 15 131 web tools 36 websites HP storage 9 11 world wide name WWN 72 99 102 115 117 120 WWN zone member 115 Z zone group check failure 121 zoning database 115 116 118 120 122 ...

Page 142: ...Index 142 Diagnostic and System Error Messages Version 3 1 x Reference Guide ...

Reviews: