SECLIB_System Error Messages
95
Diagnostic and System Error Messages Version 3.1.x Reference Guide
Message
Explanation
A security violation was reported. An unauthorized device attempted to log in
through a serial connection; the login failed.
Recommended Action
Check the serial policy and verify that the connection is allowed. If the connection
is allowed but not specified, allow connection from serial policy.
If the serial policy does not allow connection, this is a valid violation message and
an unauthorized entity is trying to access the fabric. Appropriate action should be
taken as specified by your enterprise security policy.
Note:
The serial policy controls both modem and serial access, so enabling access in
serial policy will enable both modem and serial access.
Severity
Informational
SECLIB-SECVIOL_LOGIN_SERIAL
<switch number> Info SECLIB-SECVIOL_LOGIN_SERIAL, 4, Security violation:
Login failure attempt via SERIAL.