SECLIB_System Error Messages
99
Diagnostic and System Error Messages Version 3.1.x Reference Guide
Recommended Action
Check the Security Connection Control Policy (SCC Policy specifies the WWNs
of switches allowed in the fabric) to verify which switches are allowed in the
fabric. If the switch is allowed in the fabric but is not included in the SCC policy,
add the switch to the policy.
If the switch is not allowed in the fabric, this is a valid violation message and an
unauthorized entity is trying to access the fabric. Appropriate action should be
taken as specified by your enterprise security policy.
Severity
Informational
Message
Explanation
A security violation was reported. The specified unauthorized host attempted to
perform a write SNMP operation (WSNMP).
Recommended Action
Check the WSNMP policy and verify which hosts are allowed access to the fabric
through SNMP. If the host is allowed access to the fabric but is not included in the
policy, add the host to the policy.
If the host is not allowed access to the fabric, this is a valid violation message and
an unauthorized entity is trying to access the fabric. Appropriate action should be
taken as specified by your enterprise security policy.
Severity
Informational
SECLIB-SECVIOL_WSNMP
<switch number> Info SECLIB-SECVIOL_WSNMP, 4, Security violation:
Unauthorized host with IP address <IP address> tries to do SNMP write