Diagnostic and system error messages reference guide
100
Fabric OS 3.x Document Addendum
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-MEMORY
Message
Probable Cause
The data read from the RAM location did not match previously written data into the same
location. This usually indicates a CPU RAM failure. This message is generated by the
ramtest
command. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-MEMORY, 1, <test name>,
Memory Error, Address <address value> is 0x<actual value> sb 0x<expected
value> er 0x<err value>,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...