Diagnostic and system error messages reference guide
101
Fabric OS 3.x Document Addendum
DIAG-MEMSZ
Message
Probable Cause
The memory size to be tested is less than or equal to 0. This usually indicates a motherboard
failure. This message is generated by the
ramtest
command. The
error code
value is for
internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-NOSEGMENT
Message
Probable Cause
The port failed to go into loopback mode. This message usually indicates improper cable
connections. This message is generated by the
spinsilk
command. The
error code
value is for internal use only.
Recommended Action
Verify cable connections. Reseat the SFPs and cables and then reexecute the test. Check for a
faulty cable or deteriorated SFP. Replace the cable or SFP if necessary.
<timestamp>
CRITICAL DIAG-MEMSZ, 1, <test name>,
Memory size to test <= 0,
memFindMax = <max mem size> and N_UNTESTED_RAM = <number>,
Err# <error code>
<timestamp>
CRITICAL DIAG-NOSEGMENT, 1, <test name>,
Pt<port info><speed> Failed to segment,
Please check cables,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...