Diagnostic and system error messages reference guide
104
Fabric OS 3.x Document Addendum
Probable Cause
The port is no longer transmitting, as indicated by the number of frames transmitted counter
being stuck at N frames. This can be caused by a faulty cable or deteriorated SFP. It can also
indicate more serious problems in the motherboard or ASIC. This message is generated by the
spinsilk
command. The
error code
value is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-PORTWRONG
Message
Probable Cause
The frame was erroneously received by port M instead of the intended port N. This usually
indicates an ASIC failure. This message is generated by the
portloopbacktest
command. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-PORTWRONG, 1, <test name>, pass <number>,
Frame Received at Wrong Port: is Pt<actual port> sb Pt<expected port>,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...