Diagnostic and system error messages reference guide
106
Fabric OS 3.x Document Addendum
DIAG-REGERR_UNRST
Message
Probable Cause
The port failed to un-reset. This usually indicates an ASIC failure. This message is generated
by the
portregtest
or the
sramretentiontest
command. The
error code
value
is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-STATS (C3FRX)
Message
Probable Cause
The port counter value did not match the number of frames actually transmitted. In this case,
Cl3FrmRx
equals the number of Class 3 frames received. This can be caused by a faulty
cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or
ASIC. This message is generated by the
portloopbacktest
command. The
error
code
value is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
<timestamp>
CRITICAL DIAG-REGERR_UNRST, 1, <test name>,
Pt<port info> failed to unreset despite <number> retries,
lli_ctl is <actual value> sb 90000, port_config is <actual value> sb 0,
Err# <error code>
<timestamp>
CRITICAL DIAG-STATS (C3FRX), 1, <test name>, pass <number>,
Pt<port info> Cl3FrmRx Counter Wrong, is <actual value> sb <expected
value>,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...