Diagnostic and system error messages reference guide
109
Fabric OS 3.x Document Addendum
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-TBRAM_INC_RWTEST
Message
Probable Cause
The ASIC internal registers failed the read-modify-write operation. This usually indicates an
ASIC failure. This message is generated by the
turboramtest
command. The
error
code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-TBRAM_INC_RWTEST, 1, <test name>, pass <number>,
Pt<port info> Failed TurboRAM inc r/w test:
phy=0x<address> wrd cnt=<cnt> inc size=<size> bytes
rpt=0x<actual pattern> wpt=0x<expected pattern> msk=0x<mask value>
Err# <error code>