Diagnostic and system error messages reference guide
110
Fabric OS 3.x Document Addendum
DIAG-TBRAM_WTEST
Message
Probable Cause
The ASIC internal registers failed on a write operation. This usually indicates an ASIC failure.
This message is generated by the
turboramtest
command. The
error code
value is for
internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-TIMEOUT
Message
Probable Cause
For
portloopbacktest
and
crossporttest
:
Port failed to receive frame within timeout period.
For
centralmemorytest
:
Port failed to detect an interrupt within the timeout period.
This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious
problems in the motherboard or ASIC. The
error code
value is for internal use only.
<timestamp>
CRITICAL DIAG-TBRAM_WTEST, 1, <test name>, pass <number>,
Pt<port info> Failed TurboRAM write test:
phy=0x<address> wrd cnt=<cnt> inc size=<size> bytes
wpat=0x<write pattern>
Err# <error code>
<timestamp>
CRITICAL DIAG-TIMEOUT, 1, <test name>, pass <number>,
Pt<port info> Receive Timeout,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...