Diagnostic and system error messages reference guide
119
Fabric OS 3.x Document Addendum
SEC-SECCHANGE
Message
Probable Cause
A security admin event occurred. This message is for information purposes only, but you
should verify that the event was planned. The text messages for individual events are:
■
secmodeenable
: Secure mode was enabled.
■
secmodedisable
: Secure mode was disabled.
■
secpolicyactivate
: A, B, C policies were changed. (A, B, C are names for changed
policies.)
■
secversionreset
: Secure fabric version stamp was reset.
■
secfcsfailover
: The primary FCS has failed over to a new switch.
■
All password changes: A, B, C account passwords were changed. (A, B, C are account
names for which passwords are changed.)
■
configdownload
: A configdownload was executed that changed the security policy
database.
■
secpolicysave
: A change to the security policy database was saved.
■
SNMP community string change: The admin has made a change to the SNMP community
strings.
Recommended Action
Verify that the security event was planned:
■
If the security event was planned, no action is required.
■
If the security event was not planned, investigate the action and verify that it was
authorized.
Severity
INFO
<timestamp>
INFO SEC-SECCHANGE, 4, text message
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...