Fabric OS reference guide
212
Fabric OS 3.x Document Addendum
Note:
Ensure that all users (using Fabric OS CLI or Web Tools) are logged off the fabric before
enabling secure mode. Users, whose account passwords are changed, are logged off once secure
mode is enabled. The
--currentpwd
option uses the current passwords on the primary FCS;
hence, users logged into the primary FCS are not logged off.
Operands
This command has the following operands:
list-of-switches
Specifies a list of switches for the FCS policy. The list of
member switches must be enclosed in quotation marks and
each member switch must be separated from the others by
semicolons. The members can be specified using domain,
WWN, or switch name format, as follows:
5;
10:00:00:60:69:00:00:20; star1.
--fcs
list-of-switches
Use the specified
list-of-switches
for the FCS
policy. The
list-of-switches
is a
semicolon-separated list of switches. The switches can be
specified using domain, WWN, or switch name. Specifying
*
defaults to all the switches currently in the fabric.
--currentpwd
Use the current passwords of the switch the command is run
on (the primary FCS switch) for root, factory, admin, and
user accounts. A non-FCS admin account password is set the
same as FCS admin account password. The command does
not prompt for new passwords. Only sessions whose account
password has changed are logged out. This option can be
used only on a fabric with secure mode disabled and only
when the command is run on the switch specified as the
primary FCS switch.
--lockdown
[=scc|=dcc]
Create SCC and DCC policies to lock down the fabric. SCC
policies are populated with all the switches present in the
fabric when the command was executed. DCC policies are
populated with the devices present in the fabric when the
command was executed, locking down devices on a per-port
basis. Ports with no devices attached to them are also locked
down with an empty DCC policy, so no device can be
connected to them, preserving the fabric as is. The lockdown
option creates both SCC and DCC policies; with the optional
argument of
--lockdown=scc
or
--lockdown=dcc
,
only the specified policy is created. This option can be used
only on a fabric with secure mode disabled and only when
the command is run on the switch specified as the primary
FCS switch.
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...