Fabric OS reference guide
226
Fabric OS 3.x Document Addendum
Operands
None
Example
To display the switch status:
See Also
switchstatuspolicyshow
switchstatuspolicyset
Displays temperature readings.
Syntax
tempshow
Availability
All users
Description
Use this command to display the current temperature readings from each temperature sensor
located on the switch's main printed circuit board (PCB). The sensors are located
approximately one in each corner, and one at the center of the PCB.
Operands
None
swd_152:admin>
switchstatusshow
Switch Health Report Report time: 07/22/2003 09:12:39 AM
Switch Name: swd_152
IP address: 192.168.204.152
SwitchState: HEALTHY
Duration: 00:31
Power supplies HEALTHY
Temperature sensors HEALTHY
Fans HEALTHY
Marginal ports HEALTHY
Faulty ports HEALTHY
Missing SFPs HEALTHY
All ports are healthy
tempshow