Diagnostic and system error messages reference guide
85
Fabric OS 3.x Document Addendum
Severity
CRITICAL
DIAG-CMERRPTN
Message
Probable Cause
A problem was detected at the wrong port. This usually indicates an ASIC failure. This
message is generated by the
centralmemorytest
command. The
error code
value is
for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CMERRTYPE
Message
Probable Cause
The port got the wrong CMEM error type. This usually indicates an ASIC failure. This
message is generated by the
centralmemorytest
command. The
error code
value is
for internal use only.
<timestamp>
CRITICAL DIAG-CMERRPTN, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info> Offs <offset value> <err
str> detected at wrong port,
Checking Pt<check pt>: is <actual value> sb <expected value>,
Err# <error code>
<timestamp>
CRITICAL DIAG-CMERRTYPE, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info> Offs <offset value> Wrong
Err Type,
Checking Pt<check pt>: is <actual value> (<err str>) sb <expected value>
(<err str>),
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...