Diagnostic and system error messages reference guide
87
Fabric OS 3.x Document Addendum
DIAG-CMIDATA
Message
Probable Cause
The CMI data received did not match data transmitted. This usually indicates an ASIC or
motherboard failure. This message is generated by the
cmitest
command. The
error
code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CMIINVCAP
Message
Probable Cause
The ASIC unintentionally got a CMI capture flag. This usually indicates an ASIC or
motherboard failure. This message is generated by the
cmitest
command. The
error
code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-CMIDATA, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: RX Data is <actual value>
sb <expected value> er 0x<err value>,
Err# <error code>
<timestamp>
CRITICAL DIAG-CMIINVCAP, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: Pt<fail port> erroneously
got CMI Capture Flag (bit31 is 1),
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...