Diagnostic and system error messages reference guide
88
Fabric OS 3.x Document Addendum
DIAG-CMINOCAP
Message
Probable Cause
The CMI recipient ASIC failed to get a CMI capture flag. This usually indicates an ASIC or
motherboard failure. This message is generated by the
cmitest
command. The
error
code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CMISA1
Message
Probable Cause
An attempt to send a CMI message from one ASIC to another failed. This usually indicates an
ASIC failure. This message is generated by the
cmitest
command. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-CMINOCAP, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: RX Pt<fail port> Failed to
get CMI Capture Flag (bit31 is 0),
Err# <error code>
<timestamp>
CRITICAL DIAG-CMISA1, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: TX Pt<fail port> CMI
Self-Test Start bit30 s-a-1,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...