Diagnostic and system error messages reference guide
95
Fabric OS 3.x Document Addendum
DIAG-ERRSTAT (TRUNC)
Message
Probable Cause
The Port Error Statistics counter is nonzero, which means that a
Truncated frame
error
was detected when receiving frames. This can be caused by a faulty cable or deteriorated SFP.
It can also indicate more serious problems in the motherboard or ASIC. This message is
generated by the
portloopbacktest
or
spinsilk
command. The
error code
value
is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-INIT
Message
Probable Cause
The port failed to go active in the loopback mode requested. This can be caused by a faulty
cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or
ASIC. This message is generated by the
crossporttest
,
portloopbacktest
, or
spinsilk
command. The
error code
value is for internal use only.
<timestamp>
CRITICAL DIAG-ERRSTAT (TRUNC), 1, <test name>, pass <number>,
Pt<port information> TruncFrm Error Counter is <number> sb 0,
Err# <error code>
<timestamp>
CRITICAL DIAG-INIT, 1, <test name>, pass <number>,
Pt<port information><speed> Failed to go active after initialization,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...