Diagnostic and system error messages reference guide
97
Fabric OS 3.x Document Addendum
Probable Cause
The interrupt bit could not be cleared. This usually indicates an ASIC failure. This message is
generated by the
centralmemorytest
command. The
error code
value is for internal
use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-LCMEM
Message
Probable Cause
The data read from the central memory location did not match data previously written into the
same location. This usually indicates an ASIC failure. This message is generated by the
centralmemorytest
and
cmemretentiontest
commands. The
error code
value
is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-LCMEM, 1, <test name>, pass <number>,
Pt<port information> Data Wr/Rd,
bNum 0x<buf number> bLine 0x<line number> lineOffs 0x<offset number> is
<actual value> sb <expected value> er <error value>,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...