Diagnostic and system error messages reference guide
99
Fabric OS 3.x Document Addendum
Severity
CRITICAL
DIAG-LCMTO
Message
Probable Cause
A central memory timeout occurred: data transfer initiated did not complete within the timeout
period. This usually indicates an ASIC failure. This message is generated by the
centralmemorytest
and
cmemretentiontest
commands. The
error code
value
is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-MEMNULL
Message
Probable Cause
The ASIC failed to allocate memory. This usually indicates a motherboard failure. This
message is generated by the
ramtest
command. The
error code
value is for internal use
only.
<timestamp>
CRITICAL DIAG-LCMTO, 1, <test name>, pass <number>,
Pt<port information> CMEM Timeout during a [read/write],
mem_ctl's MEM_RUNNING bit 0 Stuck High,
Err# <error code>
<timestamp>
CRITICAL DIAG-MEMNULL, 1, <test name>,
Failed to malloc memory,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...