Installing the SAN Switch 2/16
29
hp StorageWorks SAN Switch 2/16 Installation Guide
Installing the SAN Switch as a Stand-alone Unit
Use these procedures for setting up the switch as a stand-alone unit. The following
items are required for this setup:
■
SAN Switch 2/16
■
AC power cord(s) and cables supplied with the switch
■
Rubber mounting feet supplied with the switch
1. Place the SAN Switch 2/16 or on a flat, sturdy surface like a table or lab
bench.
2. Apply the rubber feet as follows.
a.
Clean the four depressions that are at each corner of the bottom of the
switch to ensure they are free of dust.
b.
Place a rubber foot in each depression, with the adhesive side against the
chassis, and press into place.
Caution:
Installing the rubber feet on the switch is recommended to help
prevent the switch from accidentally sliding off the table or bench.
3. Connect the power cable to the SAN Switch 2/16 power supply and to a power
outlet. Ensure the power cable is routed so that it is not exposed to stress.
4. Turn on the power to the switch (flip the AC switch to “1”). The switch
automatically runs a Power-On Self-Test (POST).
5. If the SAN Switch 2/16 includes a second power supply, repeat steps 3
through 5 for the remaining power supply.
Note:
Do not connect the switch to the network until the IP address is correctly set. For
instructions on how to set the IP address, see “
Configuring Network Addressing
,” later
in this chapter.
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 hp StorageWorks SAN Switch 2 16 Installation Guide ...
Page 60: ...Installing the SAN Switch 2 16 60 hp StorageWorks SAN Switch 2 16 Installation Guide ...
Page 74: ...Managing the SAN Switch 2 16 74 hp StorageWorks SAN Switch 2 16 Installation Guide ...
Page 86: ...Regulatory Compliance Notices 86 hp StorageWorks SAN Switch 2 16 Installation Guide ...
Page 94: ...Technical Specifications 94 hp StorageWorks SAN Switch 2 16 Installation Guide ...
Page 111: ......
Page 112: ......