Installing the SAN Switch 2/16
38
hp StorageWorks SAN Switch 2/16 Installation Guide
3. Slide the switch in the rack, see
Figure 7
.
Figure 7: Sliding the switch into an HP 9000 Series rack
Securing the Rack Mount Brackets
Secure the rack mount brackets (installed earlier, see “
Attaching the Rear or Front
Rack Mount Brackets
,” on page 32) to the HP 9000 Series rack rails, as follows.
1. Locate two Phillips head 10-32 x 3/8” screws in the Rack Mount Kit
accessory pouch.
2. Secure each rack mount bracket to the rack rails.
3. Tighten the screws, and torque to 25-inch pounds.
4. See the “
Connecting AC Power
” on page 45, for instructions on applying
power to the switch.
SHR-2476A