Technical Specifications
92
hp StorageWorks SAN Switch 2/16 Installation Guide
Environmental Requirements
Table 8
lists the environmental ranges that are acceptable when the switch is
operating, and the acceptable ranges when the switch is not operating.
.
Table 8: Environmental Requirements
Condition
Acceptable Range
Temperature (operating)
10°C to 40°C
Temperature (non-operating)
-35°C to 65°C
Humidity (operating)
20% to 85% RH non condensing, at
40°C
Humidity (non-operating)
0% to 90% RH non-conducting, at 40°C
Altitude (operating)
0 to 3 kilometers above sea level
Altitude (non-operating)
0 to 12 kilometers above sea level
Shock (operating)
4G, 11MS duration, half sine
Shock (non-operating)
20G, 11MS duration, sq.wave
Vibration (operating)
5G, 0-3 kHz at 1.0 octave/minute
Vibration (non-operating)
10G, 0-5kHz at 1.0 octave/minute