Installing FRUs
100
Identifying a failed CP Card
The following indicators confirm that a CP card needs to be replaced:
•
The Status LED on the CP card is yellow, or the Power LED is not ON.
•
The
slotShow
command does not show that the CP card is enabled.
•
The CP card does not respond to telnet commands, or the serial console is not available.
•
The
haShow
command indicates that the CP cards have not achieved redundancy (after 30
minutes).
•
The calendar clock is inaccurate, or the CP card does not boot up or shut down normally.
•
Any of the following messages appear in the error log:
•
Slot unknown
message relating to a CP slot
• CP card errors or I
2
C timeouts
•
FRU:
FRU_FAULTY
messages for a CP card
• Configuration loader messages or
Sys PCI config
messages
• Generic system driver messages,
FABSYS
•
Platform
system driver messages
•
EM
messages that indicate a problem with a CP card
• Function fail messages for the CP master
Recording critical switch information
Back up the switch configuration before replacing a CP card.
To record critical switch information, follow these steps:
1.
Create a serial connection to the healthy CP card:
a.
Disable any serial communication programs running on the workstation (such as
synchronization programs).
b.
Connect a serial cable to the terminal serial port (10101 Console Port).
c.
Connect the other end of the serial cable to a serial port on the workstation. If
necessary, you can remove the adapter on the serial cable to allow for a serial RJ45
connection.
Summary of Contents for StorageWorks 2/64 - Core Switch