101
Core Switch 2/64 and SAN Director 2/128 installation guide
d.
Open the terminal emulator application and configure as follows:
• Bits per second: 9600
• Databits: 8
• Parity: None
• Stop bits: 1
• Flow control: None
e.
When the terminal emulator application stops reporting information, press
Enter
.
2.
Log in to the healthy CP card as admin. The default password is
password
.
3.
Check the Active LED on the CP cards (see
Figure 16
on page 69) to determine which one
is active.
4.
Enter the
haShow
command to confirm which CP card is active.
NOTE:
Enter all remaining commands from the serial console for the active CP card, unless
otherwise indicated. For more information about commands, refer to the
HP StorageWorks
Fabric OS 4.x command reference guide
.
5.
If the healthy CP card is also the active CP card, continue with step 6; otherwise, fail over
the cards as described here:
a.
Create a serial connection to the faulty CP card.
b.
Log in to the serial console as admin.
c.
Enter the
haFailover
command.
The healthy CP card becomes the active CP card.
Fabric OS (swDir)
swDir login: admin
Password:
swDir:admin>
swDir:admin> haShow
Local CP (Slot 5, CP0): Active
Remote CP (Slot 6, CP1): Standby
HA Enabled, Heartbeat Up, State Synchronized
swDir:admin>