When shipping, or placing this product in short term storage, HP recommends maintaining the
environmental conditions listed in
Table 16
.
Table 16 Environmental shipping or short-term storage speci
fi
cations
Ambient temperature
: -40°C to +66°C (-40°F to +151°F)
Relative humidity
: 10% to 80% (noncondensing)
Altitude
: 15,240 m (50,000 ft)
Power speci
fi
cations
The input voltage to the DS2500 power supplies is a function of the country-speci
fi
c input voltage to
storage system rack power distribution units (PDUs).
Table 17
de
fi
nes the AC input power available to
the DS2500 power supplies.
CAUTION:
The AC power distribution within a rack ensures a balanced load to each PDA and reduces the possibility
of an overload condition. Changing the cabling to or from a PDM could cause an overload condition.
Table 17 DS2500 AC input line voltages
Speci
fi
cation
Minimal
Nominal
Maximum
60 Hz service
AC line frequency
57 Hz
60 Hz
63 Hz
AC line voltage—Japan
180 VAC
202 VAC
220 VAC
AC line voltage—North America
180 VAC
208 VAC
220 VAC
AC line voltage—Europe
208 VAC
240 VAC
254 VAC
50 Hz service
AC line frequency
47 Hz
50 Hz
53 Hz
AC line voltage—Japan
180 VAC
202 VAC
220 VAC
AC line voltage—North America
190 VAC
220 VAC
235 VAC
AC line voltage—North America
200 VAC
230 VAC
244 VAC
AC Line Voltage—Europe
208 VAC
240 VAC
254 VAC
66
Speci
fi
cations
Summary of Contents for StorageWorks 2500
Page 1: ...HP StorageWorks 2500 Disk System user guide Part number 5697 6800 Second edition June 2007 ...
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 44: ...44 Using the EMU ...
Page 54: ...54 Troubleshooting ...
Page 64: ...Figure 35 Replacing a disk drive 64 Customer self repair ...
Page 68: ...68 Specifications ...
Page 78: ...78 Regulatory notices ...