Table 26 Temperature threshold error conditions
Error
condition
Severity
Description
Actions
0.4.
en
.01
Noncritical
The component in location
en
is
approaching the high temperature
critical threshold.
0.4.
en
.02
Critical
The component in location
en
has
reached a temperature above the
high temperature critical threshold.
CAUTION:
Continued operation under these
conditions may result in component
failure.
1.
Ensure that all components
are properly installed to
maintain proper air
fl
ow.
2.
Ensure that nothing is
obstructing the air
fl
ow at
either the front of the enclosure
or the rear of the blowers.
3.
Ensure that both blowers
are operating properly (the
indicators are on).
Replace blower if necessary.
4.
Verify that the ambient
temperature is in the range of
10°C to 35°C (50°F to 95°F).
5.
Contact your HP-authorized
service representative.
0.4.
en
.03
Noncritical
The component in location
en
is approaching the low
temperature-critical threshold.
0.4.
en
.04
Critical
The component in location
en
has
reached a temperature below the low
temperature-critical threshold.
1.
Verify that the ambient
temperature is in the range of
10°C to 35°C (50°F to 95°F).
2.
Contact your HP-authorized
service representative.
0.4.
en
.05
Unrecoverable
The EMU has determined that the
average temperature of two of the
three component areas (EMU, disk
drives, and power supplies) exceeds
the critical level.
Enclosure shutdown is imminent.
An automatic shutdown and
possible data corruption may
result if the procedure below is not
performed
immediately
.
1.
Ensure that all components
are properly installed to
maintain proper air
fl
ow.
2.
Ensure that nothing is
obstructing the air
fl
ow at
either the front of the enclosure
or the rear of the blowers.
3.
Ensure that both blowers
are operating properly (the
indicators are on).
Replace blower if necessary.
4.
Verify that the ambient
temperature is in the range of
10°C to 35°C (50°F to 95°F).
5.
Contact your HP-authorized
service representative.
EMU error conditions
The format of an EMU error condition report is
0.7.01.ec
, where:
•
0.7.
identi
fi
es an EMU error.
•
01.
Because there is only one EMU in a DS2500, the element number is always 01.
•
ec
is the error code.
In most cases, the corrective action for an EMU error is for an HP-authorized service representative to
replace the EMU.
HP StorageWorks 2500 Disk System user guide
83
Summary of Contents for StorageWorks 2500
Page 1: ...HP StorageWorks 2500 Disk System user guide Part number 5697 6800 Second edition June 2007 ...
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 44: ...44 Using the EMU ...
Page 54: ...54 Troubleshooting ...
Page 64: ...Figure 35 Replacing a disk drive 64 Customer self repair ...
Page 68: ...68 Specifications ...
Page 78: ...78 Regulatory notices ...