108 Servicing & Upgrading
Figure 42
Array Controller Removal & Replacement Flowchart
Shutdown
the Array
Power-On
the Array
Wait 5 min.
for
Auto Clone &
Fast Reset
Resume
I/Os
S
D
Single
or Dual
Controller?
Single
or Dual
Controller?
Remove &
Replace
Controller (3)
Start
Single
or Dual
Controller?
Does
OS Support
Controller
Failover?
(1)
Stop I/Os
to Controller (2)
Remove &
Replace
Controller (3)
S
D
N
Offline
Y
Online
S
D
Notes:
(1) Consider the following:
HP-UX - Is LVM configured with alternate paths OR is
ServiceGuard configured to fail over?
WinNT - Is controller in a "cluster-safe" environment?
Win2k - Is AutoPath installed?
Linux - No Failover Support.
(2) Stop all applications and file systems OR perform
a host shutdown.
(3) Refer to "Removing/Replacing a Controller" in this
chapter.
Summary of Contents for StorageWorks 7110 - Virtual Array
Page 12: ...12 Contents ...
Page 54: ...54 Product Overview Figure 21 VA 7110 I O Architecture ...
Page 90: ...90 Troubleshooting ...
Page 116: ...116 Servicing Upgrading Figure 45 Removing Installing an Array Controller Filler Panel 1 2 3 ...
Page 129: ...Servicing Upgrading 129 Servicing Upgrading Figure 52 Removing and Installing an LCC 1 2 3 ...
Page 130: ...130 Servicing Upgrading Figure 53 Setting the FC Loop Speed Switch Must be set to 1GB s ...
Page 149: ...Specifications Regulatory Statements 149 Specifications Regulatory Statements ...
Page 151: ...Specifications Regulatory Statements 151 Specifications Regulatory Statements ...
Page 152: ...152 Specifications Regulatory Statements ...
Page 164: ...164 Index ...