132 Servicing & Upgrading
Upgrading the Array
Increasing Storage Capacity
Adding a New Disk Module
A new disk drive may be added online to the controller and disk enclosures at
any time to upgrade storage capacity in the array. See
"Installing a Disk
Drive" on page 98
to add a disk. If the Auto Include feature is enabled, the
array controller will automatically include the new disk in the array. However,
a new LUN must be created in order to make the new capacity available to the
host.
Adding Multiple Disks
If you are adding multiple disks, perform the following steps to avoid adding
multiple bad disks to the array. Each redundancy group is designed to protect
against a single disk failure. Multiple simultaneous failures can result in data
loss. Manufacturing or mishandling can cause early failures in disks. If the
disks are known to be good, they can all be installed simultaneously.
1
Install one disk module in each redundancy group (one odd slot and one
even slot).
2
Wait until the disk format operation is complete and the disks come online.
Use Command View to monitor the disk status.
3
Repeat for the next set of disks. Repeat until all disk modules have been
installed.
Adding a New Disk Enclosure (VA 7110/7400/7410 Only)
A new disk enclosure can be added to a VA 7400 or VA 7410 without
powering down the array. The disk modules in the new enclosure will be
detected by the array and will immediately be made available for use.
Here are some things to remember when adding a disk enclosure:
—
If practical, new disk enclosures should be added during a period of
lower activity. This minimizes the unlikely event that the reset generated
by the disk Fibre Channel hot plug will impact the server workload.
—
When adding a disk enclosure to a VA 7410, connect the enclosure to
the back-end FC loop that has fewer disks. Remember that the disks in
Summary of Contents for StorageWorks 7110 - Virtual Array
Page 12: ...12 Contents ...
Page 54: ...54 Product Overview Figure 21 VA 7110 I O Architecture ...
Page 90: ...90 Troubleshooting ...
Page 116: ...116 Servicing Upgrading Figure 45 Removing Installing an Array Controller Filler Panel 1 2 3 ...
Page 129: ...Servicing Upgrading 129 Servicing Upgrading Figure 52 Removing and Installing an LCC 1 2 3 ...
Page 130: ...130 Servicing Upgrading Figure 53 Setting the FC Loop Speed Switch Must be set to 1GB s ...
Page 149: ...Specifications Regulatory Statements 149 Specifications Regulatory Statements ...
Page 151: ...Specifications Regulatory Statements 151 Specifications Regulatory Statements ...
Page 152: ...152 Specifications Regulatory Statements ...
Page 164: ...164 Index ...