Servicing & Upgrading 137
Servici
ng & Upgradi
ng
1
Backup any data on the array that you wish to keep. You may also want to
record the LUN structure on the array. You will need to recreate it after
formatting the array.
2
Perform the steps in
"Upgrading Array Controller DIMMs" on page 135
,
removing or replacing DIMMs as required. The cache must be reduced on
both controllers.. After powering on the array, continue with the following
steps.
3
Check the status of the array. It should indicate No Maps.
4
Format the array using CommandView SDM or the VFP.
5
Recreate the original LUN structure on the array.
6
Reload any backed up data.
Upgrading Array Controller Firmware
(HP Service Personnel Only)
Caution
To prevent data loss, it is recommended that a full backup be
performed before starting this procedure.
Note
When downloading controller firmware, always check the
README file included with the firmware. (If you have access,
you can also read the HP Service Note associated with the
firmware download.) This information will identify whether you
can perform the firmware download offline or online.
1
Download new firmware to an active array controller using
CommandView SDM. See “Upgrading Array Controller Firmware” in the
on-line Help.
The download process copies the new firmware to the other array controller
automatically.
Note
When firmware microcode is fully downloaded, the array
controller suspends I/Os for about 10 seconds, then switches to
the new code.
Upgrading Link Controller Card Firmware
(HP Service Personnel Only)
Caution
To prevent data loss, it is recommended that a full backup be
performed before starting this procedure.
Summary of Contents for StorageWorks 7110 - Virtual Array
Page 12: ...12 Contents ...
Page 54: ...54 Product Overview Figure 21 VA 7110 I O Architecture ...
Page 90: ...90 Troubleshooting ...
Page 116: ...116 Servicing Upgrading Figure 45 Removing Installing an Array Controller Filler Panel 1 2 3 ...
Page 129: ...Servicing Upgrading 129 Servicing Upgrading Figure 52 Removing and Installing an LCC 1 2 3 ...
Page 130: ...130 Servicing Upgrading Figure 53 Setting the FC Loop Speed Switch Must be set to 1GB s ...
Page 149: ...Specifications Regulatory Statements 149 Specifications Regulatory Statements ...
Page 151: ...Specifications Regulatory Statements 151 Specifications Regulatory Statements ...
Page 152: ...152 Specifications Regulatory Statements ...
Page 164: ...164 Index ...