142 Specifications & Regulatory Statements
Table 30
Controller & Disk Enclosures Environmental Specifications
Environmental
Parameter
Controller
Enclosure
Disk
Enclosure
Temperature
Op: 5° to 35° C (41° to 95° F)
Non-Op: -40° to 70° C (-40° to 158° F)
Op: 5° to 40° C (41° to 104° F)
Non-Op: -40° to 70° C (-40° to 158° F)
Temperature
Gradient
20° C (68° F) per hour
20° C (68° F) per hour
Relative Humidity
(Dry Bulb)
Op: 15% to 80% @ 35° C (95° F)
Non-Op: 15% to 90% @ 35° C (95° F)
Op: 20% to 90% @ 26° C (78.8° F)
Non-Op: 5% to 95% @ 65° C (149° F)
Shock
Op: 4g, 11 ms, half sine
Non-Op: 2.5-inch edge drops per side
Op: 4g, 11 ms, 20 low-impulse pulses
Non-Op: 1-inch edge drops per side
Vibration
Op: 0.21g-rms, 5 to 500 Hz random
Non-Op: 2.09 g-rms, 5 to 500 Hz
random
Non-Op: 0.5 g-peak, 5 to 500 Hz swept
sine
Op: 0.21g-rms, 5 to 500 Hz random
Non-Op: 2.09 g-rms, 5 to 500 Hz
random
Non-Op: 0.5 g-rms, 5 to 500 Hz swept
sine
Altitude
Op: 0 to 10,000 ft (0 to 3,048 m)
Non-Op: 0 to 15,000 ft (0 to 4,572 m)
Op: 0 to 10,000 ft (0 to 3,048 m)
Non-Op: 0 to 15,000 ft (0 to 4,572 m)
Acoustic
(ISO 9296)
8.0 bel
8.0 bel
Summary of Contents for StorageWorks 7110 - Virtual Array
Page 12: ...12 Contents ...
Page 54: ...54 Product Overview Figure 21 VA 7110 I O Architecture ...
Page 90: ...90 Troubleshooting ...
Page 116: ...116 Servicing Upgrading Figure 45 Removing Installing an Array Controller Filler Panel 1 2 3 ...
Page 129: ...Servicing Upgrading 129 Servicing Upgrading Figure 52 Removing and Installing an LCC 1 2 3 ...
Page 130: ...130 Servicing Upgrading Figure 53 Setting the FC Loop Speed Switch Must be set to 1GB s ...
Page 149: ...Specifications Regulatory Statements 149 Specifications Regulatory Statements ...
Page 151: ...Specifications Regulatory Statements 151 Specifications Regulatory Statements ...
Page 152: ...152 Specifications Regulatory Statements ...
Page 164: ...164 Index ...