40 Product Overview
high-performance disks, and the other RG from large, slower, high-
capacity disks.
The VA 7100 and VA 7400/7410 differ in their implementation of
redundancy groups.
VA 7100/7110 Redundancy Group
The VA 7100 and VA 7110 each have one redundancy group (RG1). See
Figure 13
and
Figure 14
. All the disks in the array belong to RG1. LUNs
created from RG1 are available through both controllers (in a dual controller
configuration).
There are two internal fibre channel loops, one from each controller. The Fibre
channel disks are dual ported; each fibre channel port is connected to a
different controller. The controllers are connected via an internal high-
performance bus, which allows the LUNs to be accessed through both
controllers, and for loop or disk failover communication.
Figure 13
VA 7100 Redundancy Group
Controller 1
RG1
Host
Controller 2
RG1
Host
N-Way Bus
D2
RG1
D15
RG1
...
D1
RG1
Summary of Contents for StorageWorks 7110 - Virtual Array
Page 12: ...12 Contents ...
Page 54: ...54 Product Overview Figure 21 VA 7110 I O Architecture ...
Page 90: ...90 Troubleshooting ...
Page 116: ...116 Servicing Upgrading Figure 45 Removing Installing an Array Controller Filler Panel 1 2 3 ...
Page 129: ...Servicing Upgrading 129 Servicing Upgrading Figure 52 Removing and Installing an LCC 1 2 3 ...
Page 130: ...130 Servicing Upgrading Figure 53 Setting the FC Loop Speed Switch Must be set to 1GB s ...
Page 149: ...Specifications Regulatory Statements 149 Specifications Regulatory Statements ...
Page 151: ...Specifications Regulatory Statements 151 Specifications Regulatory Statements ...
Page 152: ...152 Specifications Regulatory Statements ...
Page 164: ...164 Index ...