Troubleshooting 77
Troubles
hooting
A Link Down warning state can be reported by the CVGUI if either of the
following two failures occur:
■
If a host Fibre Channel loop fails due to the failure of a host HBA, a faulty
or disconnected fiber cable, a faulty GBIC (VA 7100 only), or the failure of
a data flow component on an array controller.
■
If an array Fibre Channel loop fails due to a port failure on a disk drive,
faulty loop circuitry on the midplane, or the failure of a data flow
component on an array controller. If a port failure occurs, a port bypass
circuit will bypass that part of the loop and the first array controller will re-
route the data through the second array controller, via the internal N-way
bus, to the other Fibre Channel loop.
Array Power-On Sequence
Table 5 shows the power-on sequence for the array. This sequence can be
viewed via the Virtual Front Panel (VFP) when the array is powered on.
Table 5
Array Power-On Sequence
Step No. (Hex)
Description of Array Operation
02
Power-on self-test complete.
04
Check array serial number. Configure NVRAM for maps. Initialize all NVRAM on
both controllers.
06
Initialize internals.
08
Initialize array scheduler.
0A
Search for backend devices.
0C
Backend device discovery complete.
0E
Enable power supply manager to shutdown if needed.
12
Initialize maps and cache via upload from image disks. Attach array to volume set.
16
Enable hot plugging.
18
Enable warning services.
1A
Reserved.
1C
Setup internal data structures based on backend discovery.
1D
Enable frontend ports.
1E
Initialize array clocks.
20
Setup internal data structures.
22
Synchronize both controller clocks.
24
Startup complete. Enable scheduler. Allow writes to disks.
26
Initialization complete.
Summary of Contents for StorageWorks 7110 - Virtual Array
Page 12: ...12 Contents ...
Page 54: ...54 Product Overview Figure 21 VA 7110 I O Architecture ...
Page 90: ...90 Troubleshooting ...
Page 116: ...116 Servicing Upgrading Figure 45 Removing Installing an Array Controller Filler Panel 1 2 3 ...
Page 129: ...Servicing Upgrading 129 Servicing Upgrading Figure 52 Removing and Installing an LCC 1 2 3 ...
Page 130: ...130 Servicing Upgrading Figure 53 Setting the FC Loop Speed Switch Must be set to 1GB s ...
Page 149: ...Specifications Regulatory Statements 149 Specifications Regulatory Statements ...
Page 151: ...Specifications Regulatory Statements 151 Specifications Regulatory Statements ...
Page 152: ...152 Specifications Regulatory Statements ...
Page 164: ...164 Index ...