Troubleshooting 79
Troubles
hooting
Figure 25
Disk Drive LEDs (Left: VA 71/7400 A/AZ; Right: VA 7100 D)
Table 7
Disk Drive LEDs Status Indications (See Figure 25)
*Controlled by the disk drive.
**Controlled by the array controller.
Note
—
In a controller enclosure, the amber disk fault LED will flash during an
Auto Format process or when downing a disk drive. On a disk
enclosure, the amber system fault LED will also flash.
A
Disk
Activity
(Green*)
B
Disk Fault
(Amber**)
Indication
Off
Off
Disk not under power.
On
Off
Disk drive under power and operating normally.
Off
On
Disk drive fault.
On
On
Disk drive fault.
Flashing
Off
Disk drive self-test in progress
or
I/O activity.
On/Off
Flashing
Host is identifying disk drive.