80 Troubleshooting
Figure 26
VA 7100 Array Controller LEDs
Table 8
HOST FC LEDs Status Indications (See Figure 26)
Figure 27
VA 7400 Array Controller LEDs
Table 9
DISK FC & HOST FC LED Status Indications (See Figure 27)
HOST FC
GBIC Active
(Green)
HOST FC
GBIC Fault
(Amber)
Indication
Off
Off
GBIC not under power
or
link down
or
GBIC not installed.
On
Off
GBIC installed and operating normally.
Off
On
GBIC fault; GBIC not able to generate Transmit signal.
Off
Flashing
GBIC fault; GBIC has lost Receive signal.
DISK FC
Indication
Off
Unit not under power
or
disk enclosure (backend) FC link down.
On
Valid Fibre Channel link to disk enclosure.
HOST FC
Off
Unit not under power
or
host (frontend) FC link down.
On
Valid Fibre Channel link to host.