Troubleshooting 83
Troubles
hooting
Figure 30
Disk Enclosure LCC LEDs
Table 15
LCC ACTIVE & LCC FAULT LEDs Status Indications (See Figure 30)
Table 16
PORT 0 & PORT 1 LINK ACTIVE LEDs Status Indications (See Figure 30)
Table 17
2G LED (DS 2405 Disk System Only)
LCC ACTIVE
(Green)
LCC FAULT
(Amber)
Indication
Off
Off
LCC not under power.
On
Off
LCC under power and operating normally.
Off
On LCC
fault.
Flashing
Off
LCC self-test in progress.
PORT 0/PORT 1
LINK ACTIVE
(Green)
Indication
Off
LCC not under power
or
Fibre Channel link not active.
On
Fibre Channel link active.
2G (Green)
Indication
Off
FC Loop Speed set to 1 Gbit/second
On
FC Loop Speed set to 2 Gbit/second