Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable and then enable the port on
the AG to bring the port back online
as an N-Port.
N_Port between AG and Edge Switch (300) may become stuck at
E_Port Unknown state.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Fastboot a single time.
After multiple successive fastboots of an HP StorageWorks DC04 SAN
Director, there was a panic due to the zone daemon dying.
Fixed in Fabric OS 6.2.0.
FICON PTP VTS Selective Resets and Aborted sequences caused by
incorrect entry into FICON tape read pipelining.
Fixed in Fabric OS 6.2.0.
EX_Port fails to come online after downgrading firmware from Fabric
OS 6.x to 5.3 under certain conditions.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Remove the
ts.tz
parameter in the
config file and then download.
Tstimezone
settings cannot be changed or restored with
config-
download
.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Portdisable
and then enable the
EX_Ports that failed.
If a large number of EX_Ports are enabled at the same time, occasion-
ally some fail due to incompatible flow control parameters.
Fixed in Fabric OS 6.2.0.
In some instances,
portshow
may display inaccurate port authentic-
ation description or state after a CP failover.
Fixed in Fabric OS 6.2.0.
Internal server ports on embedded platform: traffic may stop due to
loss of buffer credit.
Fixed in Fabric OS 6.2.0.
The error message is cryptic when the interop fabric contains more
than 60 devices in the default zone and the user tries
cfgenablecfg-
disable
.
Fixed in Fabric OS 6.2.0.
When disabling/enabling a port, port fencing disables the port be-
cause the allowable number of invalid transmission words is exceeded.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch and
ag --show
cli will show the correct output.
Ag --show
on an HP StorageWorks 8/8 or 8/24 SAN Switch shows
incorrect edge switch IP address after a slave port is swapped with
an N-port outside of the trunk group.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use only 16-character switchname
and chassisname fields if full name
display in the logs is required.
The 32-character switchname and chassisname extensions do not fully
display in RASLog outputs, such as
errdump
or
supportsave
output.
Fixed in Fabric OS 6.2.0.
FFDC occurs when 16-31 char switch/chassis name is input on a
platform that only supports up to 15.
Fixed in Fabric OS 6.2.0.
I2C response failure and subsequent reset occasionally results in HP
StorageWorks DC SAN Backbone Director fan fault errors.
36