Fixed in Fabric OS 6.2.0d
Node descriptors are not shown for Mi10K in DCFM when a Fabric
OS switch is used as seed switch.
Fixed in Fabric OS 6.2.0d
HP StorageWorks 8/24 SAN Switch is not responding to Link Reset
primitives correctly (may send OLS and/or Link Reset).
Fixed in Fabric OS 6.2.0d
Rekey operations get stuck and progress halts.
Fixed in Fabric OS 6.2.0d
User sees a name difference between DCFM and Web Tools due to
a switch name not correctly updated at
fabricinfo.html
.
Fixed in Fabric OS 6.2.0d
Tape repositioning may be incorrect due to FICON fcip block count
mismatch on read emulation when split status responses received to
backspace block commands.
Fixed in Fabric OS 6.2.0d
LUN gets stuck in the Internal EE LUN State, and is not available for
the host until the DiscoverLUN is issued.
Fixed in Fabric OS 6.2.0d
When attempting to move ports from DCFM, some may be moved,
while others fail.
Fabric OS 6.2.0e fixes
The following table lists defects closed in the Fabric OS 6.2.0e firmware release.
Table 13 Fabric OS 6.2.0e closed defects
Solution
Closed defect summary
Fixed in Fabric OS 6.2.0e
With tape pipelining, FCR Frames can be dropped by the switch due
to specific connectivity issue resulting from losing original source ID in
the REC command. The
supportsave
command may panic occasion-
ally when Fibre Channel FastWrite (FCFW) is not enabled on the GE
port.
Fixed in Fabric OS 6.2.0e
VEX port receives bad SFID and frame cannot be routed to translate
domain due to continuous RTWR retries from backbone fabric where
fabricshow
is missing IP address.
Fixed in Fabric OS 6.2.0e
E-Port Class Link Resets are not fencing. RASLOG message will be
presented indicating link resets are above threshold, but the port will
not have been fenced as expected.
Fixed in Fabric OS 6.2.0e
RNID data reporting same serial number for two different logical
switches in FICON environment, as user entered FRU number via CLI
is not being modified.
Fixed in Fabric OS 6.2.0e
Detected termination of process fabricd:4120 followed by software
verify errors due to HP StorageWorks DC SAN Director being unre-
sponsive.
Fixed in Fabric OS 6.2.0e
Partitioned HP StorageWorks DC04 Director in FICON environment
panicked after reset allegiance issued by multiple hosts, leading to
FICUD terminating and switch reboot.
Fixed in Fabric OS 6.2.0e
SNMPd panics and generates a core file that can fill up the root file
system. User will observe snmpd process being killed and
Detected
termination of process
error message.
50