Fabric OS Reference
1-183
Telnet Commands
1
portLogDump
Display the port log without page breaks.
Synopsis
portLogDump [count[, saved]]
Availability
All users
Description
Use this command to display the port log, listing all entries in the log without page breaks. This
command displays the same information as
portLogShow
, but
portLogShow
prompts the user
to enter ‘returns” between each page.
See
portLogShow
for a description of the port log.
If the port log is disabled, the following message appears as the first line (see
portLogClear
for
details):
WARNING: port log is disabled
Operands
This command has the following operands:
count
Specify the maximum number of lines to be displayed. Only the most recent
count
entries are displayed. This operand is optional.
saved
Specify a nonzero value to display the saved port log from the last switch fault.
See
uptime
for conditions that cause a fault.
count
is ignored when displaying
the saved log. This operand is optional.
Example
To display the port log:
See Also
portLogClear
portLogShow
uptime
switch:admin> portlogdump 10
May 1 task event port cmd args
----------------------------------------------
16:51:15.499 tShell ioctl 7 de 10f9bb90,0
16:51:15.499 tShell ioctl 8 de 10f9bb90,0
16:51:15.499 tShell ioctl 9 de 10f9bb90,0
16:51:15.499 tShell ioctl 10 de 10f9bb90,0
16:51:15.499 tShell ioctl 11 de 10f9bb90,0
16:51:15.499 tShell ioctl 12 de 10f9bb90,0
16:51:15.499 tShell ioctl 13 de 10f9bb90,0
16:51:15.499 tShell ioctl 14 de 10f9bb90,0
16:51:15.499 tShell ioctl 15 de 10f9bb90,0
16:58:28.383 tShell create tSyslog
switch:admin>
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...