1-202
Fabric OS Reference
Telnet Commands
1
psShow
Display power supply status.
Synopsis
psShow
Availability
All users
Description
Use this command to display the switch power supply status.
The display format varies with switch model and number of power supplies present.
The status of each supply is shown as:
OK
Power supply present and functioning correctly.
absent
Power supply not present.
faulty
Power supply present but faulty (no power cable, power switch turned off, fuse
blown, or other internal error).
After the status line, a power supply identification line may be shown. If present, this line contains
manufacture date, part numbers, serial numbers, and other identification information.
Operands
None.
Example
To view the status of the power supply for the current switch:
See Also
fanShow
tempShow
switch:admin> psShow
Power Supply 1 is OK
9835,DH000000208,60-0000734-01, A,00001, E108302A,01, 803350
Power Supply 2 is OK
9839,DH000000253,60-0000734-01, A,00001, E108302A,01, 803522